Replace the battery door and fold out the desk stand and place the console in the upright position.
The unit will instantly display indoor temperature, humidity, pressure, tendency, moon phase, and time.
The wind speed, wind gust, wind direction, rain, UV/Sunlight, thermo-hygrometer sensors, Integrated
outdoor temperature and humidity will update on the display within a few minutes. Do not Press any
menu buttons until the outside transmitter report in, otherwise the outdoor sensor search mode will be
terminated. When the outdoor transmitter data has been received, the console will automatically switch to
the normal mode from which all further settings can be performed.
While in the search mode, the remote search icon
will be constantly displayed.
If you have more than one thermo-hygrometer sensor (up to eight thermo-hygrometer sensors are
supported), the display will automatically toggle between sensors until all sensors have reported in.
If it does not update, please reference the troubleshooting guide in Section 18.
Note:
The power adapter is intended to be correctly oriented in a vertical or floor mounted position. The
prongs are not designed to hold the plug in place if it is plugged into a ceiling, under-the-table or cabinet
outlet.
Figure 12
Note:
If the power adapter is plugged in,
BL ON
will display in the time area for three seconds when
powered up. Conversely, if the power adapter is not plugged in,
AC OFF
will be displayed, the icon
will
display.
3.4.2 Sensor Operation Verification
The following steps verify proper operation of the sensors prior to installing the sensor array.
1. Verify proper operation of the rain gauge. Tip the sensor array back and forth several times. You should
hear a
“clicking”
sound within the rain gauge. Verify the rain reading on the display console is not reading
0.00. Each
“click”
represents 0.3mm of rainfall.
2. Verify proper operating of the wind speed. Rotate the wind cups manually or with a constant speed fan.
Verify the wind speed is not reading 0.0.
3. Verify proper operation of the indoor and outdoor temperature. Verify the indoor and outdoor
temperature match closely with the console and sensor array in the same location
(about 3m apart). The sensors should be within 2°C (the accuracy is ±1°C). Allow about 30 minutes for