To tal Cur rent Con sump ti on of In ter fa ces
The total current consumption at
5V interfaces
must not exceed
5A
.
each COM* = 300mA, in total 500mA
each USB = 500mA, in total 2A
each USB (HUB) = 500mA, in total 2A
TFT/LCD-Display
Max. 5A @ 5V
The total current consumption at
12V interfaces
must not exceed
5A
.
each COM* = 600mA, in total 900mA
each USB = 1,5A, in total 2A
each USB (HUB) = 1,5A, in total 2A
TFT/LCD-Display
Max. 5A @ 12V
The total current consumption at
24V interfaces
must not exceed
3A
.
each USB (HUB) = 3,0A, in total 3,0A
DC24V
Max. 3A @ 24V
Power loss of additionally implemented PCI- and PCIe- Controllers is - for
thermic reasons - limited to 10W for each slot and all together to 20W.
40