To tal Cur rent Con sump ti on Of In ter fa ces
The total current consumption at
5V interfaces
must not exceed
5A
.
each COM* = 300mA, in total 1000mA
each USB = 500mA, in total 2A
each USB (Hub) = 500mA, in total 2A
Max. 5A @ 5V
The total current consumption at
12V interfaces
must not exceed
5A
.
each COM*(2/3/4/5) = 600mA, in total 900mA
each COM*(6/7) = 600mA, in total 900mA
each PUSB 12V (*) = 3A
each PUSB 12V = 1.5A
Max. 5A @ 12V
The total current consumption at
24V interfaces
must not exceed
3A
.
each PUSB 24V = 3,0A
Max. 3A @ 24V
Power loss of implemented PCI- Controller is - for thermic reasons - limited
to 10W.