CALIFORNIA EVAPORATIVE EMISSION CONTROL

WARRANTY STATEMENT

YOUR WARRANTY RIGHTS AND OBLIGATIONS

The California Air Resources Board is pleased to explain the evaporative emission control system’s warranty on your model 
2020 generator. In California, new equipment that uses small off-road engines must be designed, built, and equipped 
to meet the State’s stringent anti-smog standards. WINCO must warrant the evaporative emission control system on 
your generator for the period listed below provided there has been no abuse, neglect or improper maintenance of your 
equipment leading to the failure of the evaporative emission control system.

Your evaporative emission control system may include parts such as: carburetor, fuel tank, fuel cap, fuel lines (for liquid fuel 
and fuel vapors), fuel line fittings, fuel line clamps, carbon canisters, and carbon canister mounting brackets.

MANUFACTURER’S WARRANTY COVERAGE

The evaporative emission control system is warranted for two years. If any evaporative emission related parts on your 
equipment are defective, the parts will be repaired or replaced by WINCO.

WINCO warrants to the original purchaser for 36 months or 1000 hours, whichever occurs first, that goods manufactured 
or supplied by it will be free from defects in workmanship and material, provided such goods are installed, operated and 
maintained in accordance with WINCO written instructions and applicable codes. 

WINCO’s sole liability, and Purchaser’s sole remedy for a failure under this warranty, shall be limited to the repair of the 
product. At WINCO’s option, material found to be defective in material or workmanship under normal use and service 
will be repaired or replaced. For warranty service, return the product within the warranty period, to your nearest WINCO 
Authorized Service Center or to WINCO in Le Center Minnesota. 

Duration Consumer, Commercial and Rental

Parts & Labor: 24 Months
Parts Only: 24-36 Months

EXCLUSIONS:

•   Normal maintenance consumables or labor.
•  This warranty does not cover travel time, mileage or labor for removal or re-installation of WINCO product from its 
 application. 
•  Normal wear and tear.
•  Costs of rental equipment. 
•  WINCO does not warrant engines. Engines are covered exclusively by the warranties of their respective manufacturers. 
•  WINCO does not warrant component parts that are warranted by their respective manufacturers. 
•  WINCO does not warrant modifications or alterations which were not made by WINCO. 
•  WINCO does not warrant products which have been subjected to misuse and/or negligence or have been involved in 
 

an accident. Proof of proper maintenance must be furnished upon request. 

THERE ARE NO EXPRESS WARRANTIES OTHER THAN THOSE DESCRIBED HEREIN. THERE ARE NO OTHER 
WARRANTIES, EXPRESSED OR IMPLIED, OR OTHERWISE CREATED, INCLUDING BUT NOT LIMITED TO WARRANTIES OF 
MERCHANTABILITY, OR WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE.

WINCO is liable for the repair or replacement of the product only and is not liable for incidental or consequential damages 
as permitted by your state. This warranty gives you specific legal rights which may vary from state to state. 

ENGINE GENERATOR SET 

36 MONTH 

LIMITED WARRANTY

Summary of Contents for W6010DE/I

Page 1: ...ver need to contact us concerning this unit it will help us to respond to your needs faster MODEL ________________________________________________ SERIAL NUMBER _______________________________________...

Page 2: ...TROUBLESHOOTING 18 WIRING DIAGRAM 19 CA EVAP EMISSION CONTROL 20 LIMITED WARRANTY 20 SAVE THESE INSTRUCTIONS This manual contains important instructions that should be followed during installation an...

Page 3: ...sent a hazard of possible explosion and or fire A Do not refuel when the engine is running or hot B Keep fuel containers out of reach of children C Do not smoke or use open flame near the generator se...

Page 4: ...0DE I J 43 21 5 W6010KE 03 A 40 20 GENERATOR Generator Manufacturer Mecc Alte Spa Generator Model Number S16W 130 A Part Number 16346 006 Rotor Resistance 3 95 Ohms Stator Resistance 0 360 Ohms Cap Wi...

Page 5: ...ED USES DO NOT operate generator where it could get wet or have pooling water near it This generator is NOT weatherproof Failing to keep generator in a dry area may cause an electrical shock resulting...

Page 6: ...esent the 120 volt output legs of this generator Up to 2 580 watts at 120 volts 43 Amps can be drawn from the receptacles attached to either A or B output legs This generator is capable of producing 2...

Page 7: ...evel be sure you properly tighten the oil fill cap NOTE This engine generator must be on a level surface before you check or add oil to the system The necessity of using the correct oil and keeping th...

Page 8: ...ry presents a risk of electrical shock and high short circuit current The following precautions must be observed when working with batteries 1 Remove watches rings and other metal objects 2 Use tools...

Page 9: ...as a battery charging circuit to recharge dead batteries LIFTING EYE INSTALLATION In the bag of parts for the lifting eye ensure all of the required materials are included 2 qty 5 16 18 x 2 25 button...

Page 10: ...osition The lever is located under the key switch as pictured 3 Turn key to 1st position Ref A 4 Turn key to the 2nd position starting Ref B A B 5 Return key to 1st position when engine is running Ref...

Page 11: ...revent damage to either the receptacles or the generator The generator is a limited source of electrical power therefore pay special attention to the receptacle and generator ratings The nameplate rat...

Page 12: ...stored while the generator is connected This generator is GFCI protected so the transfer switch needs to be GFCI compatible If the transfer switch is not GFCI compatible the breaker on the generator w...

Page 13: ...ual are approximately as follows under varying loads LOAD vs OUTPUT Generator Load Speed RPM Frequency Hz Voltage 120V Recpt 240V Recpt None 3690 61 5 125V 258V Half 3600 60 0 120V 240V Full 3510 58 5...

Page 14: ...s generator is capable of producing 21 5 Amps of 240 volt current at C Check the appliance or tool nameplates for the current and voltage to insure compatibility Remember that power taken from C reduc...

Page 15: ...Check dry air cleaner Fuel tank cleaning Clean cooling fins Replace engine oil Replace oil filter Replace fuel filter Set and clean injectors Rocker arm adjustment Drain Bolt C Replace oil drain plug...

Page 16: ...is excessively dirty replace with a new filter You can use pressurized air not to exceed 30 psi to clean the filter Always blow the compressed air from inside to the outside F Clean the dirt from the...

Page 17: ...ubrication B Receptacles Quality receptacles have been utilized If a receptacle should become cracked or otherwise damaged replace it Using damaged or cracked receptacles can be both dangerous to the...

Page 18: ...uit breaker trips Defective load Defective receptacle Excessive load GFCI type of load i e a building with bonded neutral Voltage too high Engine speed is too high Generator overheating Overloaded Ins...

Page 19: ...19 OPM 133 E WIRING DIAGRAM...

Page 20: ...nd Purchaser s sole remedy for a failure under this warranty shall be limited to the repair of the product At WINCO s option material found to be defective in material or workmanship under normal use...