18
OPM-133/E
TROUBLESHOOTING
Problem
Possible Causes
Won’t start
Low oil level
Out of fuel
Start switch in OFF position
Fuel Valve turned off
Plugged fuel filter
Blown fuse in key switch
Battery required to open solenoid
Voltage too low
Engine speed is too low
Generator overloaded
Defective stator
Defective rotor (field)
Defective capacitor
Circuit breaker trips
Defective load
Defective receptacle
Excessive load
GFCI type of load i.e. a building with
bonded neutral
Voltage too high
Engine speed is too high
Generator overheating
Overloaded
Insufficient ventilation
No output voltage
Short in load (disconnect)
Tripped or defective circuit breaker
Broken or loose wire
Defective receptacle
No residual magnetism (in
generator)
Defective stator
Defective rotor (field)
Shorted capacitor
Shorted diodes on rotor
GFCI receptacle tripped
Will not shutdown
Fuel solenoid valve lever is in up
position