  applicable codes. The electrician will move the critical 

 

  circuits to be powered during the outage to the 

 

  emergency panel. Keep in mind only a limited 

 

  amount of amperage is available from the generator 

 

  set. Some circuit breakers may still have to be turned 

 

  off to prevent an overload on the generator during 

 

  the initial start up. See the nameplate on your 

 

  generator for the amperage capabilities of your unit.

CAUTION: EQUIPMENT DAMAGE

Failure to properly limit and balance the load applied to 

the generator will cause the generator to produce low 

voltage and may damage the engine generator set. It 

may also cause severe damage to the loads connected 

to the generator at that time. Improper loading of the 

generator set constitutes abuse and will not be covered 

by warranty.

Summary of Contents for HPS9000VE-03/A

Page 1: ...d to contact us concerning this unit it will help us to respond to your needs faster MODEL _________________________________________________ SERIAL NUMBER _________________________________________ PUR...

Page 2: ...ING THE OIL DUAL ELEMENT AIR FILTER SPARK PLUG CARBON CANISTER TROUBLESHOOTING 18 GENERATOR CARE 18 EXERCISING THE GENERATOR GENERATOR MAINTENANCE CLEANING RECEPTACLE WIRING DIAGRAM 19 CA EVAP EMISSIO...

Page 3: ...ber S20W 110 Part Number 16346 009 Rotor Resistance 5 22 Ohms Stator Resistance 0 21 Ohms Cap Winding Resistance 0 87 Ohms Capacitors 35 mF Capacitor Part Number 300323 212 ENGINE Engine Manufacturer...

Page 4: ...he earth 2 FIRE HAZARD Gasoline and other fuels present a hazard of possible explosion and or fire A Do not refuel when the engine is running or hot B Keep fuel containers out of reach of children C D...

Page 5: ...nce these units should never be run in small compartments without positive fresh air flow RESTRICTED USES DO NOT remove from the cradle assembly Removal of the generator from the cradle assembly may c...

Page 6: ...rs take about the same amount of current to run them whether they are Repulsion Induction RI Capacitor Cap or Split Phase SP type If the electric motor is connected to a hard starting load such as an...

Page 7: ...per lubricant are considered abuse and not covered by the generator or engine manufacturer s warranty OIL RECOMMENDATIONS Outdoor temperatures determine the proper oil viscosity for the engines Winco...

Page 8: ...on without having to shut off the manual valve The fuel line used to connect the supply line to the demand regulator must be a locally approved flexible fuel line Products used will vary in different...

Page 9: ...one fuel to another FROM GASOLINE TO LP NG 1 With the engine running turn off the gasoline fuel valve 2 Run the engine until it runs out of fuel 3 Remove the plastic insert from the demand regulator...

Page 10: ...ill automatically stop the engine before the oil level reaches a critical danger point This feature is designed to prevent costly repairs and downtime CAUTION EQUIPMENT DAMAGE Allowing the engine to s...

Page 11: ...ging circuit For your safety always connect the positive battery cable to the bat terminal first Then connect the negative battery cable to the bat terminal Make sure all connections are clean and tig...

Page 12: ...n pull briskly 6 When the engine starts open the choke gradually 7 The engine should promptly come up to operating speed NOTICE Do not allow the starter grip to snap against the engine Return it gentl...

Page 13: ...the fuel system it is almost impossible to manual start the unit using NG 1 Check oil level refill as needed 2 Turn on the LP NG fuel supply 3 NEVER use the choke when operating on NG 4 Turn the engin...

Page 14: ...do so could result in damage to equipment plugged into the unit and possible injury to the individual All engines have a tendency to slow down when a load is applied When the electrical load is connec...

Page 15: ...d on the generator or the vehicle PERMANENTLY INSTALLED GENERATORS This WINCO portable generator ships with a bonded neutral and overcurrent protection NFPA 70 refers to this as a separately derived s...

Page 16: ...load on the generator during the initial start up See the nameplate on your generator for the amperage capabilities of your unit CAUTION EQUIPMENT DAMAGE Failure to properly limit and balance the load...

Page 17: ...dipstick when filling the engine with oil to prevent overfilling E Replace filler plug F Start engine up and warm it up G After warming up the engine recheck the oil level and refill as necessary to...

Page 18: ...he high pressure spray could contaminate the fuel system and the generator components 1 Keep the air inlet screen on both the engine and generator free of any dirt or debris to ensure proper cooling A...

Page 19: ...19 60706 237 G G1 G1 G3 G3 RECEPTACLE WIRING DIAGRAM...

Page 20: ...quest THERE ARE NO EXPRESS WARRANTIES OTHER THAN THOSE DESCRIBED HEREIN THERE ARE NO OTHER WARRANTIES EXPRESSED OR IMPLIED OR OTHERWISE CREATED INCLUDING BUT NOT LIMITED TO WARRANTIES OF MERCHANTABILI...