10
60706-237/G
this minimum acceptable size, the size of LP tank used will
generally depend on how long you want the unit to run
without refilling. Keep in mind the colder it gets, the slower
LP will vaporize. This is the reason for the larger tanks at low
temperatures. Minimizing sizing is NOT based on running
time.
Temp (F)
60°
30°
0°
-20°
150 gal
250 gal
500 gal
1000 gal
OIL ALERT SYSTEM
This generator is equipped with a low oil shutdown system.
The Briggs & Stratton engine uses a float switch mounted
inside the engine. If the oil level drops below a certain point,
the low oil module on the engine will shut it down. This oil
warning system will automatically stop the engine before
the oil level reaches a critical danger point. This feature is
designed to prevent costly repairs and downtime.
CAUTION: EQUIPMENT DAMAGE
Allowing the engine to shutdown repeatedly on low
oil level, may cause excessive wear which can be
cumulative.
OPTIONAL DOLLY KIT
An optional dolly kit is available for this generator. The dolly
kit comes with instructions and a parts list. After installing
the dolly kit, file the instructions and parts list in the back of
this manual for future reference.
OPTIONAL FUEL SOLENOID KIT
An optional 12 Volt DC fuel solenoid kit is available for
this generator. This solenoid kit will automatically shut off
the fuel supply should the engine stop for any reason,
preventing fuel leaks. This kit is recommended if you are
going to be operating the generator unattended.