13
60706-237/G
7. Gradually move choke to the open position as the
engine warms up.
8. The engine should promptly come up to operating
speed.
CAUTION: EQUIPMENT DAMAGE
Never permit the choke to remain on after the engine
has run for a short time. It is not necessary to choke the
engine when it is warm. Avoid over-chocking.
NATURAL GAS
ELECTRIC STARTING
When operating on LP or NG, you will have to always
use the electric start to get the unit running. Because the
engine vacuum needs to activate the fuel system it is almost
impossible to manual start the unit using NG.
1. Check oil level, refill as needed.
2. Turn on the LP/NG fuel supply.
3. NEVER use the choke when operating on NG.
4. Turn the engine switch to the ‘on’ position.
5. Operating the starter. Rotate the key switch briefly to
START position. The starter life is improved by using
shorter starting cycles with time to cool off between
cranking cycles. Do NOT operate the starter more
than 5 seconds and wait at least 10 seconds before
operating the starter again. Repeat cycle if necessary.
6. When the engine starts, release the key switch,
allowing it to return to the ‘on’ position.
7. The engine should promptly come up to operating
speed.