Winco HPS12000HE/F Installation And Operator'S Manual Download Page 5

5

3240

60706-236

Self-exciting generators respond to severe overload-

ing differently than utility power.  When overloaded, 

the engine is not able to supply enough power to 

bring the electric motor up to operating speed.  The 

generator responds with high initial starting current, 

but the engine speed drops sharply.  The overload 

may stall the engine.  If allowed to operate at very 

low speeds, the electric motor starting winding will 

burn out in a short time.  The generator winding may 

also be damaged.

CAUTION:  EQUIPMENT DAMAGE

  RUNNING THE GENERATOR SET UNDER 

THESE CONDITIONS MAY RESULT IN DAMAGE 

TO THE GENERATOR STATOR AS WELL AS THE 

MOTOR WINDING.

The heavy surge of current required for starting 

motors is required for only an instant.  The genera-

tor will not be damaged if it can bring the motor up 

to speed in a few seconds of time.  If difficulty is 

experienced in starting motors, turn all other electri-

cal loads off and if possible reduce the load on the 

electric motor.

PREPARING THE UNIT

UNPACKING

CAUTION:  EQUIPMENT DAMAGE

    THIS UNIT HAS BEEN SHIPPED 

WITHOUT OIL

.  

Failure to maintain the engine oil at the proper level 

will result in serious engine damage.

When you unpack your new engine-generator set be  

sure to remove all the information sheets and manu-

als from the carton.

1.  This generator-set was in good order when 

shipped.  Inspect the generator-set promptly after 

receiving it.  If any damage is noted, notify the trans-

portation company immediately; request proper pro-

cedures for filing a “concealed damage” claim.  Title 

to the equipment and responsibility for filing a claim 

rests with you when a generator-set is sent F.O.B. 

shipping point.  Only you can legally file a claim.

2.  Before proceeding with the preparations of your 

new generator-set for operation, take a couple of 

minutes to ensure the unit you have received is the 

correct model and review the specification pages in 

this manual to ensure that this unit meets your job 

requirements.

LUBRICATION

Before starting the engine, fill the crankcase to the 

proper level with a good quality oil.  The recom-

mended grade of oil and quantity of oil required is 

listed in the engine operator’s manual and under 

oil recommendations below.  This unit was shipped 

with most of the oil removed.  The engine normally 

holds 57 and 58 ounces of oil.  Since there is some 

trapped oil in the engine, when filling the crankcase 

the first time use the dipstick to ensure that you do 

not over fill the crankcase. The picture below shows 

the full oil level mark on the dipstick.   

Oil is added to the engine by removing the oil filler 

cap and adding oil at this point.  After filling the 

crankcase to the proper level be sure you properly 

tighten the oil fill cap.  NOTE:  This engine generator 

must be on a level surface before you check or add 

oil to the system. 

 

The necessity of using the correct oil, and keeping 

the crankcase full cannot be overemphasized.  En-

gine failures resulting from inadequate or improper 

lubricant are considered abuse and not covered by 

the generator or engine manufacturer’s warranty. 

 

Oil Recommendations 

Outdoor temperatures determine the proper oil 

viscosity for the engines. Use the chart to select the 

best viscosity for the outdoor temperature range 

expected. 

 

ENGLISH

ENGINE OIL

Recommended Oil

Oil Level Check

Oil Change

AMBIENT TEMPERATURE

OIL FILLER

CAP

UPPER LIMIT
LOWER LIMIT

OIL LEVEL DIPSTICK

UPPER

LIMIT

LOWER

LIMIT

SEALING WASHER

DRAIN BOLT

OIL FILLER CAP

OIL LEVEL DIPSTICK

Synthetic 5W-30

8

Use 4-stroke motor oil that meets or exceeds the requirements for
API service category SJ or later (or equivalent). Always check the
API service label on the oil container to be sure it includes the
letters SJ or later (or equivalent).

Check the engine oil level with the engine stopped and in a level
position.

Start the engine and let it idle for 1 or 2 minutes. Stop the engine
and wait for 2 or 3 minutes.

Remove the oil level dipstick and wipe it clean.

Fully insert the oil level dipstick, then remove it to check the oil
level.

If the oil level is low, remove the oil filler cap, and fill with the
recommended oil to the upper limit mark on the oil level dipstick.

Reinstall the oil level dipstick and oil filler cap.

The Oil Alert system (applicable types) will automatically stop the
engine before the oil level falls below the safe limit. However, to
avoid the inconvenience of an unexpected shutdown, always
check the engine oil level before startup.

Oil is a major factor affecting performance and service life.
Use 4-stroke automotive detergent oil.

Drain the used oil when the engine is warm. Warm oil drains
quickly and completely.

Place a suitable container below the engine to catch the used oil,
then remove the oil filler cap, drain bolt and sealing washer.

Allow the used oil to drain completely, then reinstall the drain
bolt and new sealing washer, and tighten the drain bolt securely.

Please dispose of used motor oil in a manner that is compatible
with the environment. We suggest you take used oil in a sealed
container to your local recycling center or service station for
reclamation. Do not throw it in the trash, pour it on the ground,
or pour it down a drain.

Reinstall the oil filler cap and oil level dipstick securely.

The Oil Alert system (applicable types) will automatically stop
the engine before the oil level falls below the safe limit.
However, to avoid the inconvenience of an unexpected
shutdown, fill to the upper limit, and check the oil level regularly.

With the engine in a level position, fill with the recommended oil
to the upper limit mark on the oil level dipstick.

Running the engine with a low oil level can cause engine damage.

This type of damage is not covered by the

Distributor’s Limited

Warranty.

Running the engine with a low oil level can cause engine

damage. This type of damage is not covered by the

Distributor’s

Limited Warranty.

SAE 10W-30 or 5W-30 is recommended for general use. Use a full
synthetic 5W-30 for starting/operating temperatures between 5°F
( 15°C) and

13°F ( 25°C). Other viscosities shown in the chart

may be used when the average temperature in your area is within
the indicated range.

1.

2.

3.

4.

5.

1.

2.

3.

4.

09/07/07 20:34:57 32Z6L600_008

ENGLISH

ENGINE OIL

Recommended Oil

Oil Level Check

Oil Change

AMBIENT TEMPERATURE

OIL FILLER

CAP

UPPER LIMIT
LOWER LIMIT

OIL LEVEL DIPSTICK

UPPER

LIMIT

LOWER

LIMIT

SEALING WASHER

DRAIN BOLT

OIL FILLER CAP

OIL LEVEL DIPSTICK

Synthetic 5W-30

8

Use 4-stroke motor oil that meets or exceeds the requirements for
API service category SJ or later (or equivalent). Always check the
API service label on the oil container to be sure it includes the
letters SJ or later (or equivalent).

Check the engine oil level with the engine stopped and in a level
position.

Start the engine and let it idle for 1 or 2 minutes. Stop the engine
and wait for 2 or 3 minutes.

Remove the oil level dipstick and wipe it clean.

Fully insert the oil level dipstick, then remove it to check the oil
level.

If the oil level is low, remove the oil filler cap, and fill with the
recommended oil to the upper limit mark on the oil level dipstick.

Reinstall the oil level dipstick and oil filler cap.

The Oil Alert system (applicable types) will automatically stop the
engine before the oil level falls below the safe limit. However, to
avoid the inconvenience of an unexpected shutdown, always
check the engine oil level before startup.

Oil is a major factor affecting performance and service life.
Use 4-stroke automotive detergent oil.

Drain the used oil when the engine is warm. Warm oil drains
quickly and completely.

Place a suitable container below the engine to catch the used oil,
then remove the oil filler cap, drain bolt and sealing washer.

Allow the used oil to drain completely, then reinstall the drain
bolt and new sealing washer, and tighten the drain bolt securely.

Please dispose of used motor oil in a manner that is compatible
with the environment. We suggest you take used oil in a sealed
container to your local recycling center or service station for
reclamation. Do not throw it in the trash, pour it on the ground,
or pour it down a drain.

Reinstall the oil filler cap and oil level dipstick securely.

The Oil Alert system (applicable types) will automatically stop
the engine before the oil level falls below the safe limit.
However, to avoid the inconvenience of an unexpected
shutdown, fill to the upper limit, and check the oil level regularly.

With the engine in a level position, fill with the recommended oil
to the upper limit mark on the oil level dipstick.

Running the engine with a low oil level can cause engine damage.

This type of damage is not covered by the

Distributor’s Limited

Warranty.

Running the engine with a low oil level can cause engine

damage. This type of damage is not covered by the

Distributor’s

Limited Warranty.

SAE 10W-30 or 5W-30 is recommended for general use. Use a full
synthetic 5W-30 for starting/operating temperatures between 5°F
( 15°C) and

13°F ( 25°C). Other viscosities shown in the chart

may be used when the average temperature in your area is within
the indicated range.

1.

2.

3.

4.

5.

1.

2.

3.

4.

09/07/07 20:34:57 32Z6L600_008

Summary of Contents for HPS12000HE/F

Page 1: ...INSTALLATION AND OPERATORS MANUAL TRI FUEL GENERATOR HPS12000HE F...

Page 2: ...k Sizing for LP 8 Changing Fuel Types 8 Battery Installation 9 INITIAL START UP 10 Electric Starting for Gasoline 10 Electric Starting for LP NG 11 Stopping Storage 11 Operating Speed 11 CONNECTING TH...

Page 3: ...en c Do not smoke or use open flame near the generator set or fuel tank d Keep a fire extinguisher nearby and know its proper use Fire extinguishers rated ABC by NFPA are appropriate e Store fuel only...

Page 4: ...OTE There are 3rd party companies making enclosures for generators that have been properly engineered The use of these 3rd party enclosures is acceptable as long as they have been certified and meet c...

Page 5: ...e on a level surface before you check or add oil to the system The necessity of using the correct oil and keeping the crankcase full cannot be overemphasized En gine failures resulting from inadequate...

Page 6: ...the inlet of the fuel demand regulator on the unit using a locally approved flexible fuel line see table for recommended line size The pressure supplied to the demand regulator must be FOUR TO SIX OUN...

Page 7: ...ts Excessive sealing compound can be drawn into the solenoid regulator or carburetor causing an engine malfunc tion or dangerous fuel leak FUEL CONSUMPTION Full Load Gasoline 1 67 Gal HR LP Vapor 2 2...

Page 8: ...S These engine generator sets are designed to run on three different fuels gasoline natural gas or LP vapor They may be easily changed from one fuel to another FROM GASOLINE TO LP NG 1 With the engine...

Page 9: ...ing the battery in an enclosed space Lead acid batteries contain sulfuric acid which causes severe burns If acid contacts eyes skin or clothing flush well with water For con tact with eyes get immedia...

Page 10: ...the engine switch to the START position and hold it there until the engine starts If the engine fails to start within 5 seconds release the engine switch and wait at least 10 seconds before operating...

Page 11: ...o could result in damage to equipment plugged into the unit and possible injury to the individual ENGLISH STOPPING THE ENGINE M MI IN N M MI IN N START ENGINE SWITCH START ENGINE SWITCH THROTTLE LEVER...

Page 12: ...rator and any load connected to it Running the engine at ex cessively high speeds results in high voltage which may significantly shorten the life of appliances being used Output voltage should be che...

Page 13: ...olt portable appliances and tools to be plugged directly into them Please note that the 4 wire 240 volt receptacle on these units are designed to power both 120 or 240 volt loads The plug for this rec...

Page 14: ...nce problems that result from using a fuel with percentages of ethanol or methanol greater than shown above are not covered under the Warranty If your equipment will be used on an infrequent or interm...

Page 15: ...occur if spark plug wire does not fit firmly on spark plug If this happens reform the ter minal to fit firmly on spark plug tip 5 Carbon Canister Designed to collect store and dispose of fuel vapors...

Page 16: ...ken or loose wire Defective receptacle No residual magnetism in generator Defective stator Defective rotor field Shorted capacitor Shorted diodes on rotor GFCI Receptacle tripped GENERATOR SPECIFICATI...

Page 17: ...17 3240 60706 236 CONTROL PANEL WIRING DIAGRAM...

Page 18: ...arest WINCO Authorized Service Center or to WINCO Inc at Le Center Minnesota THERE IS NO OTHER EXPRESS WARRANTY To the extent permitted by law any and all warranties including those of merchantability...

Page 19: ...ER S WARRANTY COVERAGE The evaporative emission control system is warranted for two years If any evaporative emission related parts on your equipment are defective the parts will be repaired or replac...

Page 20: ...2240 00 20 60706 236 WINCO INC 225 S CORDOVA AVE LE CENTER MN 56057 507 357 6821 SERVICE DEPT 507 357 6831 www wincogen com...

Reviews: