Follow these same instructions for each well of a two well unit. Each well 

operates independently and may be operated at different temperatures.
1.  The EFT-32 requires the use of two cords. Be sure to unplug both 

cords prior to moving, testing or repairing this product.

2.  Remove basket(s) (I) from fryer.
3.  Insert  Wire Mesh Heating Element Cover (M) (Figure 5)

x

x

Fire hazard.

Overheated oil or oil vapors can ignite causing a fire. 

Monitor oil temperature, quality and level. Use and 

maintain oil vapor removal system.

WARNING

Operation

4.  Fill or add oil/solid shortening to the Well (F). Always maintain oil 

level between High Oil Level (C) and Low Oil Level (D) as indicated 

on the Element Holder Vertical Support Bracket (J).  

(See Figure 1) 

Do not

 under-fill or over-fill.

5.  Adjust the Thermostat Control Dial (A) to the desired temperature; 

the Temperature Ready Light (G) indicates when the elements 

are energized. If solid shortening is used, pack the fat around the 

heating element and set the temperature between 200~250°F 

so the fat will melt slowly as it covers the heating elements. The 

melted fat should not exceed the high level mark nor should it drop 

below the low level mark found on the Element Holder Vertical 

Support Bracket (J). This will reduce smoking and risk of fire.

6.  Allow the oil to preheat and come up to recommended cooking 

temperature. The Temperature Ready Light (G) will cycle off when 

the oil has reached the set temperature.

Oil Tips

1.  Use oil that is recommended for frying foods.
2.  Cook at temperatures that are recommended by food manufacturer.
3.  Change oil when oil becomes 

noticeably darkened

 from food 

particles that burn when subjected to prolonged heat.

4.  Change oil when there is a noticeable foul odor or when the oil 

smells like the food cooked in it.

5.  To re-use oil, use a few layers of cheese cloth to filter excess 

particles only after oil has cooled.

6.  Cover oil overnight using the Well Cover (M) provided.

 
Safety Reset Switch

The units are equipped with a switch that cuts off power if the oil 

temperature reaches 430°F (221°C). This switch has a manual reset. 

The reset switch is located on the back of the unit (Figure 2). 
The switch will activate if the oil temperature reaches 430°F. Before 

resetting the safety switch, check for these causes.
Possible causes for the safety reset switch to activate are:

•  Dirty oil

•  Too little oil in fry well

•  Heating elements not in proper lowered position

to rESEt thE tEmpEraturE SaFEty Switch:

1.  Wait until the oil has cooled to 300°F (149°C) or below.
2.  Remove the switch cover by unscrewing counterclockwise. 
3.  Use a pen or similar narrow tool and press the reset button down. 

The button should stay in the depressed position.

4.  Replace the switch cover and secure by screwing clockwise. 

If unable to reset the safety reset switch or the safety reset 

switch continues to trip, contact WINCO Technical Service.

Figure 6. Removing / Replacing Electrical Power Head

Removeable 

Electrical Power 

Head slips easily 

into and out of  

the holder on the 

back of the unit

O

Figure 5. Insert Wire Mesh Heating Element Cover (M)

1. Place two rear 

wire feet inside 

heating element in 

spot A.

2. Push two front 

wire feet over 

heating element at 

the front, so feet 

are just outside 

the heating 

element in spot B.

A

B

1.

2.

A

B

7.  Dry food product or remove ice crystals from food prior to frying.
8.  Load each basket; NEVER more than half way full.
9.  Carefully lower the basket into the cooking oil. Food should 

remain in fryer as per manufacturers recommended cooking time.

10.  When food is finished, hook the basket on the Basket Support Bar 

(K) using the Basket Hooks (L).  

This will allow the excess oil to drain back into the well. Prepare 

as directed by food manufacturer.

Summary of Contents for EFS-16

Page 1: ...e outlet is required for each fryer head Two separate dedicated 20 Amp circuits with a single outlet for each fryer head is required BEFORE OPERATING ANY EQUIPMENT READ AND FAMILIARIZE YOURSELF WITH T...

Page 2: ...Warranty 11 Fire Safety Information 12 Package Contents AllunitscomewithaUse CareManual warrantyregistrationcardandthefollowingasnoted EFS 16 EFS 16unit includesbaseandremovableelectricalpowerheadwith...

Page 3: ...Function and Purpose Thisunitisintendedtobeusedfordeepfryingfoodsincommercial food serviceoperationsonly Itisnotintendedforhousehold industrialorlaboratoryuse Beforeusingthisequipmentitmustbecleaneda...

Page 4: ...he powersupplypriortoservicebyqualifiedtechnician TheEFS 32mustalwayshavebothcordspluggedinforproper operation or bothcordsunpluggedpriortoany maintenanceor serviceoftheequipment NEVERleaveonecordplug...

Page 5: ...Removable WELL Figure1 Holdstheoilandiswherethe cookingtakesplace Theheatingelementissuspendedinthis component TEMPERATURE READY LIGHT Figure1 Thislightindicates thattheelementisheating Oncethetempera...

Page 6: ...il smellslikethefoodcookedinit 5 Tore useoil useafewlayersofcheeseclothtofilterexcess particlesonlyafteroilhascooled 6 CoveroilovernightusingtheWellCover M provided Safety Reset Switch Theunitsareequi...

Page 7: ...lyaftercleaning NOTE A very small amount of soap left in the well can ruin the oil Any water remaining in the well will cause violent boiling and sputtering when oil is hot 13 CleaningtheHeatingElemen...

Page 8: ...e dirtyoil toolittleoilinfrywell orheatingelementsnotinproperloweredposition or Referto SafetyResetSwitch sectionofthis manual Ifproblempersists callforservice Oilgetstoohot Oillevellow Turnunitoff al...

Page 9: ...EFT 32 LIMIT SWITCH 20 5A 125V T125 SAFETY RESET SWITCH 446 F 230 C 16A 250V T125 POWER SUPPLY 120V AC 60Hz GROUND POWER INDICATOR LAMP 120V GREEN TEMPERATURE READY LIGHT 120V RED THERMOSTAT 122 374 F...

Page 10: ...tos CA 90703 Phone 1 888 946 2652 EastoftheMississippiRiver contact CustomerService WINCO 65IndustrialRoad Lodi NJ 07644 Phone 1 888 946 2682 E mail warranty wincous com Limited Equipment Warranty 3 Y...

Page 11: ...heoilto cool reducingtheflashpointtemperatureandmakingiteasierto stopthefire Immediately cover the well with the well cover and or heavy non flammable blanket or canvas Thiswillcutoffoxygentothefire C...

Page 12: ...WINCO DWL Industries Co 12...

Page 13: ...de friteuse Deux distincts circuits sp ciaux de 20 amp res avec une prise unique pour chaque t te de friteuse est n cessaire AVANT DE FAIRE FONCTIONNER UN QUIPEMENT LISEZ ET VOUS FAMILIARISEZ AVEC LE...

Page 14: ...22 Informations de s curit pour incendie 23 Contenus dans le package Touteslesunit ssont quip esd unmanueld utilisationetd entretien unecarted enregistrementdegarantieetlasuivantecommeindiqu EFS 16 U...

Page 15: ...n treutilis seulementpourdesalimentsde fritureenservicesalimentairescommerciaux Iln estpasdestin usagedomestique industrieloudelaboratoire Avantd utilisercet quipementnilfautlenettoyerets cher compl t...

Page 16: ...que d incendie Lasurchauffedesvapeursd huileoudel huilepeuts enflammeret provoquerunincendie Surveillezlatemp rature laqualit etle niveaud huile Utilisezetentretenezlesyst med liminationdes vapeursd h...

Page 17: ...s dansethorsdel unit d liminationdeshuilesetdenettoyage PUITSAMOVIBLE Figure1 C estlaplacepourcontenirl huileetr aliser lacuisson L l mentchauffantestsuspendudanscettecomposante VOYANTDEPRETDETEMPERAT...

Page 18: ...esetdes curit oule boutonResetdes curit continue sed clencher contactezavecle ServicetechniqueWINCO Figure6 Retrait remplacementdelat ted aliemntation lectrique La t te d aliemntation lectrique amovib...

Page 19: ...ul esurl l mentchauffant s P ilpeut trebr l enactionnantl appareilavecunpuits sec 250 F 121 1 C pendantquelquesminutes Lafriteuse s arr teautomatiquement quiservira galementcommeun testdel interrupteu...

Page 20: ...itsdefriture oules l mentsdechauffage nesontpasenpositioncorrecte ou Reportez vous InterrupteurReset des curit de cemanuel Sileprobl mepersiste contactezleservice L huileesttropchaude Leniveaud huilee...

Page 21: ...e course 20 5A 125V T125 Interrupteur reset de s curit 446 F 230 C 16A 250V T125 ALIMENTATION ELECTRIQUE 120V CA 60Hz TERRE Voyant d alimentation lectrique 120V Vert Voyant de pr t de temp rature 120V...

Page 22: ...NCO 12765 166 meRue Cerritos CA 90703 T l 1 888 946 2652 Garantie Limite d Equipement EstdelaRivi reMississippi contactezavecle Servicedeclient le WINCO 65 RueIndustrielle Lodi NJ 07644 T l 1 888 946...

Page 23: ...sserl huilerefroidir r duirelatemp raturedepoint d clairetlerendreplusfaciled arr terlefeu Couvrez imm diatement le puits avec le couvercle de puits et ou la couverture ou toile lourd non inflammable...

Page 24: ......

Reviews: