background image

EC6010DR/T

EC6010KE-03/B 

GENERATORS

INSTALLATION AND 

OPERATORS MANUAL

COPY YOUR MODEL AND SERIAL NUMBER HERE

No other WINCO generator has the same serial number as yours. 

If you should ever need to contact us on this unit, it will help us to 

respond to your needs faster.

MODEL __________________________________________________

SERIAL NUMBER _________________________________________ 

PURCHASE DATE _________________________________________

DEALER NAME ___________________________________________

DEALER PHONE # ________________________________________

16200-014

Summary of Contents for EC6010DR/T

Page 1: ...ould ever need to contact us on this unit it will help us to respond to your needs faster MODEL __________________________________________________ SERIAL NUMBER _______________________________________...

Page 2: ...CLEANING TROUBLESHOOTING 18 CONTROL PANEL WIRING DIAGRAM 19 CA EVAP EMISSION CONTROL 20 LIMITED WARRANTY 20 SAVE THESE INSTRUCTIONS This manual contains important instructions that should be followed...

Page 3: ...sent a hazard of possible explosion and or fire A Do not refuel when the engine is running or hot B Keep fuel containers out of reach of children C Do not smoke or use open flame near the generator se...

Page 4: ...store the unit outside during inclement weather without adequate protection from the elements Failure to do so will damage the unit DO NOT remove from the cradle assembly Removal of the generator fro...

Page 5: ...ceptacles attached to either A or B output legs This generator is capable of producing 21 5 Amps of 240 volt current at C Check the appliance or tool nameplates for the current and voltage to insure c...

Page 6: ...to refuse the shipment and let WINCO take care of the freight claim If you sign for the unit the transfer of the ownership requires that you file the freight claim 2 Before proceeding with the prepara...

Page 7: ...e hydrogen gas when charging Keep sparks flames and burning cigarettes away from the battery Ventilate the area when charging or using the battery in an enclosed space Lead acid batteries contain sulf...

Page 8: ...battery with water use only distilled water Tap water will shorten the service life of the battery Never fill the battery above the fill line Overfilling above the upper level line may cause the elec...

Page 9: ...reen wire connects to the skid base There may already be a ground wire screwed down add the green wire and re secure the screw The black longer wire will connect to the front of the engine Attach blac...

Page 10: ...Preferred fuel installations use 1 4 hose that run straight to the engine with no drops or twists from an adequately sized fuel tank Connect a 1 4 fuel hose to the hose fitting located on the fuel pum...

Page 11: ...nd dry area 0 INITIAL START UP The throttle control on these generators is preset and locked to operate at 3600 RPM nominal with no load speed set at 3690 RPM Only a trained service technician should...

Page 12: ...system When connecting it to a building a transfer switch specifically designed for GFCI and bonded neutral generators is required CONNECTING THE LOADS The engine generator covered in this manual was...

Page 13: ...set is connected to an existing distribution system a fully isolated manual transfer switch must be installed The transfer switch prevents damage to the generator and the other circuit components if...

Page 14: ...5 25 50 50 75 75 100 YOURGEN The WINCO YourGen meter allows you to see useful information about your generator from the front panel by displaying RPMs Voltage frequency load hours and maintenance remi...

Page 15: ...This generator is capable of producing 21 5 Amps of 240 volt current at C Check the appliance or tool nameplates for the current and voltage to insure compatibility Remember that power taken from C r...

Page 16: ...with the air filter removed A Remove the cover ENGINE CARE MAINTENANCE SCHEDULE Daily or Every 10 hrs Every 250 hrs Every 500 hrs Check Oil Check oil filter Check dry air cleaner Fuel tank cleaning C...

Page 17: ...is excessively dirty replace with a new filter You can use pressurized air not to exceed 30 psi to clean the filter Always blow the compressed air from inside to the outside F Clean the dirt from the...

Page 18: ...generator components 1 Keep the air inlet screen on both the engine and generator free of any dirt or debris to ensure proper cooling At least yearly remove the blower housing on the engine and clean...

Page 19: ...19 OPM 125 D CONTROL PANEL WIRING DIAGRAM G1 G1 G1 G2 G N N G G G2 G2...