Definition for tJIT(cc) and tJIT(cc,lck)
t
JIT(cc)
is defined as the absolute difference in clock period between two consecutive clock cycles.
t
JIT(cc)
= Max of |{t
CK
i +1 - t
CK
i}|.
t
JIT(cc)
defines the cycle to cycle jitter when the DLL is already locked.
t
JIT(cc,lck)
uses the same definition for cycle to cycle jitter, during the DLL locking period only.
t
JIT(cc)
and t
JIT(cc,lck)
are not subject to production test.
Definition for tERR(nper)
t
ERR
is defined as the cumulative error across n multiple consecutive cycles from t
CK(avg)
. t
ERR
is not
subject to production test.
10.15 Speed Bins
DDR3 SDRAM Speed Bins include t
CK
, t
RCD
, t
RP,
t
RC
and t
RAS
for each corresponding bin.
10.15.1 DDR3-1333 Speed Bin and Operating Conditions
Speed Bin
DDR3-1333
UNIT
NOTES
CL-nRCD-nRP
9-9-9
Part Number Extension
-15/15I
Parameter
Symbol
Min.
Max.
Maximum operating frequency using maximum
allowed settings for Sup_CL and Sup_CWL
f
CKMAX
667
MHz
Internal read command to first data
t
AA
13.5
(13.125) *
9
20
nS
ACT to internal read or write delay time
t
RCD
13.5
(13.125) *
9
nS
PRE command period
t
RP
13.5
(13.125) *
9
nS
ACT to ACT or REF command period
t
RC
49.5
(49.125) *
9
nS
ACT to PRE command period
t
RAS
36
9 * t
REFI
nS
CL = 6
CWL = 5
t
CK(AVG)
2.5
3.3
nS
1, 2, 3, 4, 6
CWL = 6, 7
t
CK(AVG)
Reserved
nS
5
CL = 7
CWL = 5
t
CK(AVG)
Reserved
nS
5
CWL = 6
t
CK(AVG)
1.875
< 2.5
nS
1, 2, 3, 4, 6
(Optional) *
9
nS
CWL = 7
t
CK(AVG)
Reserved
nS
5
CL = 8
CWL = 5
t
CK(AVG)
Reserved
nS
5
CWL = 6
t
CK(AVG)
1.875
< 2.5
nS
1, 2, 3, 4, 6
CWL = 7
t
CK(AVG)
Reserved
nS
5
CL = 9
CWL = 5, 6
t
CK(AVG)
Reserved
nS
5
CWL = 7
t
CK(AVG)
1.5
< 1.875
nS
1, 2, 3, 4, 6
CL = 10
CWL = 5, 6
t
CK(AVG)
Reserved
nS
5
CWL = 7
t
CK(AVG)
1.5
< 1.875
nS
1, 2, 3, 4, 6
Supported CL Settings
Sup_CL
6,
(7)
, 8, 9, 10
nCK
Supported CWL Settings
Sup_CWL
5, 6, 7
nCK
Note: