WilTec SKD-1 with cord Operation Manual Download Page 6

Wiring diagram for connecting various pump motors to the automatic machines:

Wiring diagram for single-
phase 220V pumps up to 1.1 
kW

Wiring diagram for single-
phase 220V pumps over 1.1 
kW Control via 2-phase relay 
(contactor), relay selection 
according to pump perfor-
mance

Wiring diagram for three-phase
400V pumps also over 1.1 kW 
Control via 3-phase relay (con-
tactor), selection of relay ac-
cording to pump capacity

Possible errors and their elimination:

Error

Error at the machine

Error outside the machine

Pump does not start

-

Board is damaged

-

Missing voltage

-

Pump defective

-

Replaced electrical cables

Pump does not stop

-

Board is damaged

-

The flow detector is stuck in the up-
per position.

-

The reset button is blocked.

-

The pump does not have sufficient 
pressure

-

There is a leak with more 
than 0.6 l/min loss.

Intermittent pump 
work

-

Board is damaged

-

The pump does not have sufficient 
pressure

-

There is a leak with more 
than 0.6 l/min loss.

© by WilTec Wildanger Technik GmbH 

Seite 6 

http://www.WilTec.de
http://www.aoyue.eu

  January 2020 Version 7

http://www.teichtip.de

Summary of Contents for SKD-1 with cord

Page 1: ...ow the operating instructions and safety information before using for the first time Technical changes reserved Due to further developments illustrations functioning steps and technical data can diffe...

Page 2: ...AX notification 49 2403 55592 15 from ________________________________________ Name ________________ Firm _____________________ Tel Fax __________________ I would like to report the following mistakes...

Page 3: ...ver lift transport or attach the device to the power cord Make sure that the electrical plug connections are located in a flood proof area or are pro tected from moisture Disconnect the mains plug bef...

Page 4: ...ror will reoccur immediately or after a short time Possible causes A The water pressure of the pump used is not sufficient to operate the water pressure switch Causes can be a blockage a worn pump bod...

Page 5: ...est valve to protect the piping system from pres sure loss Do not place any extraction points between the pump and the Automat Pump Pressure The automat is set to an inlet pressure of 1 5 bar The pump...

Page 6: ...rs and their elimination Error Error at the machine Error outside the machine Pump does not start Board is damaged Missing voltage Pump defective Replaced electrical cables Pump does not stop Board is...

Page 7: ...nts out that this article must not be treated as normal household waste but must be disposed to a recycling collection point for electronic and electrical waste equipment By contributing to the correc...

Reviews: