Technical Data - Specifications:

Input Voltage

220-250V  / 50 Hz / Max. 10A

Max. pressure

10 bar

Max. temperature 

60°C

Connections

25,4 mm external threads

Protection class

IP 65

Functional description of the general operating mode of the pump control:
The pump control consists of a pressure switch and a water flow switch. The switching cycles are then
determined from the two switching states of the pressure switch and the water flow switch.

Water pressure switch ac water flow switch not actuated = normal switch-off (delay of 

approx. 3-8 sec. until switch-off).

Wasser

 

water pressure switch not ac water flow switch actuated = pump on

Water pressure switch not ac water flow switch not actuated = switch-off due to dry 

running and indication of fault. (delay 8-15 seconds)

Common causes of errors:

First problem case:
The pump control switches off and displays failure/error even though water was pumped successfully 
before. After a reset, this error will reoccur immediately or after a short time.
Possible causes:
A: The water pressure of the pump used is not sufficient to operate the water pressure switch. 
(Causes can be a blockage, a worn pump body or a pump that is too weak).
B: The water pressure switch in the pump control is blocked. (Cleaning with clean water can solve the 
problem or the housing of the pressure switch in the pump control must be cleaned. Sand and other 
sediments may have deposited here.)

Second problem case:
The pump control leaves the pump permanently switched on regardless of whether the tap is open or 
closed.
Possible causes:
A: The installation position of the pump control was not taken into account. This does not reset the wa-
ter flow switch and it is permanently actuated. (Check installation position and correct if necessary.
B: The water flow switch at the pump control input is permanently actuated. This can be caused by 
contamination, calcification or a foreign body. (An optical check confirms this problem and can be cor-
rected by cleaning.)

© by WilTec Wildanger Technik GmbH 

Seite 4 

http://www.WilTec.de
http://www.aoyue.eu

  January 2020 Version 7

http://www.teichtip.de

Summary of Contents for SKD-1 with cord

Page 1: ...ow the operating instructions and safety information before using for the first time Technical changes reserved Due to further developments illustrations functioning steps and technical data can diffe...

Page 2: ...AX notification 49 2403 55592 15 from ________________________________________ Name ________________ Firm _____________________ Tel Fax __________________ I would like to report the following mistakes...

Page 3: ...ver lift transport or attach the device to the power cord Make sure that the electrical plug connections are located in a flood proof area or are pro tected from moisture Disconnect the mains plug bef...

Page 4: ...ror will reoccur immediately or after a short time Possible causes A The water pressure of the pump used is not sufficient to operate the water pressure switch Causes can be a blockage a worn pump bod...

Page 5: ...est valve to protect the piping system from pres sure loss Do not place any extraction points between the pump and the Automat Pump Pressure The automat is set to an inlet pressure of 1 5 bar The pump...

Page 6: ...rs and their elimination Error Error at the machine Error outside the machine Pump does not start Board is damaged Missing voltage Pump defective Replaced electrical cables Pump does not stop Board is...

Page 7: ...nts out that this article must not be treated as normal household waste but must be disposed to a recycling collection point for electronic and electrical waste equipment By contributing to the correc...

Reviews: