WilTec SKD-1 with cord Operation Manual Download Page 5

Notes on installation:

© by WilTec Wildanger Technik GmbH 

Seite 5 

http://www.WilTec.de
http://www.aoyue.eu

  January 2020 Version 7

http://www.teichtip.de

If the water column between 
the pump and the highest 
point of the pipe exceeds 15 
meters, the automat cannot 
be installed directly at the 
pump. The machine must 
then be installed at a height 
where the overhanging wa-
ter column is shorter than 15
meters. For example: If the 
water column is 20 meters, 
the machine must be in-
stalled at least 5 meters 
above the pump.

The machine is equipped 
with a test valve to protect 
the piping system from pres-
sure loss.

Do not place any 
extraction points between 
the pump and the Automat.

Pump 
Pressure

The automat is set to an 
inlet pressure of 1.5 bar. The
pump inlet pressure must 
normally be 0.5 bar higher 
than the starting pressure, 
i.e. at least 2 
bar.

Before the start of 
the machine the 
suction hose and the 
pump filling must be 
checked!

     We recommend 
connecting the pump 
control to the house 
water pipe via a flexi-
ble hose.

The safety valve to 
prevent water leakage 
if the diaphragm bursts
(do not work on or 
change!).

The control must be 
oriented upwards ac-
cording to the direction
of the arrow.

The controller can be 
installed directly on the
pump or between the 
pump and the first tap-
ping point.

Summary of Contents for SKD-1 with cord

Page 1: ...ow the operating instructions and safety information before using for the first time Technical changes reserved Due to further developments illustrations functioning steps and technical data can diffe...

Page 2: ...AX notification 49 2403 55592 15 from ________________________________________ Name ________________ Firm _____________________ Tel Fax __________________ I would like to report the following mistakes...

Page 3: ...ver lift transport or attach the device to the power cord Make sure that the electrical plug connections are located in a flood proof area or are pro tected from moisture Disconnect the mains plug bef...

Page 4: ...ror will reoccur immediately or after a short time Possible causes A The water pressure of the pump used is not sufficient to operate the water pressure switch Causes can be a blockage a worn pump bod...

Page 5: ...est valve to protect the piping system from pres sure loss Do not place any extraction points between the pump and the Automat Pump Pressure The automat is set to an inlet pressure of 1 5 bar The pump...

Page 6: ...rs and their elimination Error Error at the machine Error outside the machine Pump does not start Board is damaged Missing voltage Pump defective Replaced electrical cables Pump does not stop Board is...

Page 7: ...nts out that this article must not be treated as normal household waste but must be disposed to a recycling collection point for electronic and electrical waste equipment By contributing to the correc...

Reviews: