background image

 

https://www.naturewater.eu 

 

Item 52365

 

Page 6 

 

 

  

 

11 2022-1

 

 

Inverting function of the control panel

 

 

The side labelled IN of the automatic sediment filter must be the inlet. You can open the upper cover of 
the filter to determine the correct installation position of the inlet and outlet with the help of the IN and 
OUT symbols. Depending on the installation conditions and the different position of the inlet and outlet, 
the control panel can be inverted as shown.

 

 

1.

 

To do so, remove the upper cover of the lid 
of the housing.

 

2.

 

Use  a  screwdriver  to  untighten  the  two 
screws of the control panel.

 

3.

 

Lift  the  entire  control  panel  and  turn  it  by 
180°. While doing so, make sure not to dam-
age the connection valve and electric cable 
attached to the card.

 

4.

 

Fix  the  control  panel  at  the  corresponding 
position  in  the  opposite  direction  and  re-
tighten the two screws.

 

5.

 

Re-place the lid onto the valve and screw it 
tight.

 

 

1

 

Remove the two screws to turn the control 
panel.

 

 
 

Bracket

 

 

Included in the scope of delivery, there are a metal 
bracket and two brass connection pieces with that 
you attach the filter to the pipe. You can fix the filter 
to a wall or frame construction (as shown).

 

 

Before fixing the filter to the pipe, you should attach 
it at the bracket first by using the two brass connect-
ors; only then attach it to the pipe.

 

 

Attention!

 If using a hard pipe (e.g., PPR or metal 

pipe) for the connection, you must fix the filter to the 
bracket first; otherwise, the filter cannot be fixed.

 

 

1

 

Bracket

 

2

 

Brass connection pieces

 

 

Summary of Contents for 52365

Page 1: ...nstructions and safety information before using for the first time Technical changes reserved Illustrations functional steps and technical data may deviate insignificantly due to continuous further developments Updating the documentation If you have suggestions for improvement or have found any irregularities please contact us ...

Page 2: ...have found an error or wish to suggest an improvement we look forward to hearing from you Send us an e mail to service wiltec info or use our contact form https www wiltec de contacts The most recent version of this manual in several languages can be found in our online shop https www wiltec de docsearch Our postal address is WilTec Wildanger Technik GmbH Königsbenden 12 52249 Eschweiler Germany T...

Page 3: ...t this might provoke defor mations and damages to non metal components The device can only be used together with cold water Do not install it in a warm water conduct Do not use this filter together with water coming from an unknown source Only use it for tap water The sediment filter can be used together with communal water Make sure that the transparent filter housing does not come into contact w...

Page 4: ...er must be connected to the tap water source of your house behind the water level indicator to be able to clean the entire supply of drinking water In case there is a water softening or a heating system this system must be preceded by the automatic sediment filter as shown in the following illustration old water pipe Heating Water softening device Warm water pipe Automatic sediment filter Unfilter...

Page 5: ...hall last The electric control system works with a standard transformer or with 6 V batteries The control panel indicates a low tension and the sign EE in case the battery requires to be replaced To avoid any battery replacement it is recommended to use the transformer The tissue of the standard filter sieve is 60 micron However you can also choose a 100 micron or 150 micron filter sieve if necess...

Page 6: ... so make sure not to dam age the connection valve and electric cable attached to the card 4 Fix the control panel at the corresponding position in the opposite direction and re tighten the two screws 5 Re place the lid onto the valve and screw it tight 1 Remove the two screws to turn the control panel Bracket Included in the scope of delivery there are a metal bracket and two brass connection piec...

Page 7: ...igh speed when flushing Moreover there must be an air gap of approx 4 cm between the end of the drain pipe and the bottom sieve This gap can prevent that wastewater be sucked back into the filter The drain pipe cannot be inserted into the bottom sieve Installation requirement for drain pipe The drain pipe should not exceed 3 m of length and be short and straight otherwise it could impair the autom...

Page 8: ...utlet in the centre of the floor grid and fix it correctly 7 4 cm air gap 8 Floor grid About the earth cable when connecting to a metal pipe In certain houses metal pipes are used as earth cables to avoid electric shocks When connecting the automatic sediment filter to such a metal pipe it will destroy the circuit To avoid this you can use a copper wire firmly clamped into a metal pipe and linked ...

Page 9: ...hine begins to flush Pay as well attention to the air gap Tightness check 1 After the installation open the water supply valve 2 Make sure that all connectors are tight 3 Make sure that the circuitry is dry before switching the device on Battery installation battery not included 1 Insert the 4 AA batteries into the battery compartment 2 Remove the cover and make sure that the device is vertical 3 ...

Page 10: ...than the one included in the scope of delivery To install the power supply unit do the following steps 1 Remove the cover 2 Remove the battery compartment installed then unplug the battery connection plug very im portant 3 Plug the round plug of the power supply unit into the socket of the card 4 onnect the power supply unit to the mains 5 Put the power supply cable into the cable slot of the inle...

Page 11: ...s LCD background lighting When pressing one of the keys the L D background lighting is lit To save energy the L D background lighting is turned off if during 10 s no other key has been pressed Starting the device up 1 When starting the device up the screen will indicate the software version number for a short moment e g 01 2 After that it indicates the days of flush cycle e g 7 and in the meantime...

Page 12: ...Set mode is shown disengage the key The Set mode is activated the days of flushing cycle are shown 2 Press the SET key once shortly to increase the day value by 1 After the day value has been increased to 30 the value will return to 0 With the value set to 0 the automatic flushing function is deactivated however you can press the LEAN key to start flushing by hand 3 When the screen shows the day v...

Page 13: ...by 1 2 Press the SET key once shortly to increase the day value by 1 5 Do not press any key for 10 s Then return to the Work mode The values 8 days and 61 s are shown 3 Press LEAN key Flushing time 1 The days of flushing cycle have been reached 2 Press LEAN key Sec Set SET LEAN Automatic Flush Filter Automatic Flush Filter Automatic Flush Filter Work Work Day Set Second Setting Second Setting Sec ...

Page 14: ...aintenance Cleaning the filter sieve At times it might be necessary to clean the filter in particular when the water contains clay or mud To do so remove the filter housing and clean the filter on a regular basis If for certain reasons the auto matic sediment filter has not been flushed for a longer time it is advisable that you clean the filter by hand to avoid any obstruction 1 Before closing th...

Page 15: ... close it again 11 Make sure that no water leaks off the housing Replacing the siliphos filter In case there is no longer a sufficient quantity of siliphos the limescale prevention effect is impaired Buy a new siliphos filter Name explanation 1 Housing 2 Screw off clockwise after having released the water pressure ...

Page 16: ...With siliphos filter The central drain pipe is found inside the siliphos filter Name Name 1 Housing cover 1 Housing cover 2 entral drain pipe 2 Siliphos filter 3 ruciform mounting bracket 3 Small stainless steel net 4 O ring 4 O ring 5 Housing 5 Housing 6 O ring 6 O ring 7 Large filter 7 Large filter ...

Page 17: ... other European countries with a separate waste collection system for these devices The symbol on the packaging or the product itself indi cates that this product must not be treated as normal domestic waste but must be disposed of at a recycling collection station for electrical and electronic waste By disposing of this product correctly you contribute to the protection of the environment and the...

Reviews: