background image

The information contained in this document may alter at any time without previous notice. It is prohib-
ited to copy or spread any parts of this document in any way without prior written allowance. All rights
reserved.
The WilTec Wildanger Technik GmbH cannot be held accountable for any possible mistakes in this
operating manual, nor in the diagrams and figures shown.
Even though, the WilTec Wildanger Technik GmbH has undergone biggest possible efforts to ensure
that the operating manual is complete, faultless and up to date, mistakes cannot be entirely avoided.
If you should find a mistake or wish to make a suggestion for improvement, we look forward to hearing
from you.

Send an e-mail to:

[email protected]

or use our contact form:

https://www.wiltec.de/contacts/

The most recent version of this manual in various languages can be found in our online shop via:

https://www.wiltec.de/docsearch

Our postal address is:

WilTec Wildanger Technik GmbH
Königsbenden 12
52249 Eschweiler
Germany

Do you wish to pick goods up? Our pick-up address is:

WilTec Wildanger Technik GmbH
Königsbenden 28
52249 Eschweiler
Germany

To shorten the waiting time and allow for a rapid on-site transaction, we ask you to call us previously
or placing your order via the webshop.

E-mail: [email protected]
Tel:+49 2403 55592-0
Fax: +49 2403 55592-15

To return orders for exchange, repair or for other purposes, please use the following address. Atten -
tion! To allow for a smooth execution of your complaint or return, it is important to contact our cus -
tomer service team before returning the goods.

Returns Department
WilTec Wildanger Technik GmbH
Königsbenden 28
52249 Eschweiler

E-mail: 

[email protected]

Tel:+49 2403 55592-0
Fax: +49 2403 55592-15

© by WilTec Wildanger Technik GmbH 

Item 50374–50377

Page 2 

http://www.WilTec.de
http://www.aoyue.eu

 

11 2020-1

http://www.teichtip.de

Summary of Contents for 50374

Page 1: ... operating instructions and safety information before using for the first time Technical changes reserved Due to further developments illustrations functioning steps and technical data can differ insignific antly Updating the documentation If you have suggestions for improvement or have found any irregularities please contact us ...

Page 2: ...uages can be found in our online shop via https www wiltec de docsearch Our postal address is WilTec Wildanger Technik GmbH Königsbenden 12 52249 Eschweiler Germany Do you wish to pick goods up Our pick up address is WilTec Wildanger Technik GmbH Königsbenden 28 52249 Eschweiler Germany To shorten the waiting time and allow for a rapid on site transaction we ask you to call us previously or placin...

Page 3: ...hey are supervised by a person responsible for their safety or have obtained instructions on how to use the device Children should be supervised to ensure that they do not play with the device Attention Perform a visual inspection of the device before each use Do not use the device if safety devices are damaged or worn Never override safety devices Only use the device in accordance with the intend...

Page 4: ...avoided Electrical connection The electrical connection is made to an earthed socket with 230 V 50 Hz Fusing at least 6 A The motor is protected against overloading or blocking by the built in thermal motor protection If the device is overheating the motor overheating protection automatically switches off the pump after it has cooled down the pump switches on again automatically Make sure that the...

Page 5: ...suction and pressure lines must never rest on the pump Make sure that all connections are tight so that the pump does not come into contact with moisture and possibly be damaged We recommend the installation of a foot valve When setting up make sure that the pump is not self priming Operation 1 Fill the system with water to find and repair any leaks 2 Open any slide valves in the pressure and suct...

Page 6: ...electric pumps do not require any special maintenance Please empty the dirt container regularly The pump body should be emptied before the cold season and if the system is not used for a longer period If the system is not used at all for a long period of time the pump must be cleaned rinsed thoroughly with clean tap water and stored in a dry and well ventilated place Residues of chlorine and other...

Page 7: ... bar Max 1 1 bar Temperature range 0 35 C liquid 0 35 C liquid 0 35 C liquid 0 35 C liquid Particle width 3 mm 3 mm 3 mm 3 mm Line connection 32 mm 38 mm 11 4 11 2 32 mm 38 mm 11 4 11 2 32 mm 38 mm 11 4 11 2 32 mm 38 mm 11 4 11 2 Protection class IPX4 IPX4 IPX4 IPX4 Cable length 1 5 m 1 5 m 1 5 m 1 5 m Weight 4 8 kg 5 6 kg 9 8 kg 10 8 kg by WilTec Wildanger Technik GmbH Item 50374 50377 Page 7 htt...

Page 8: ...s out that this article must not be treated as normal house hold waste but must be disposed to a recycling collec tion point for electronic and electrical waste equip ment By contributing to the correct disposal of this art icle you protect the environment and the health of your fellow men Environment and health are threatened by inappropriate disposal Materials recycling helps reduce the consumpt...

Page 9: ...enden EG Rats Richtlinien übereinstimmt This appliance is in conformity with the following European directives Cet appareil est conforme aux directives européennes 2014 35 EU Es ist nach folgenden harmonisierten Normen geprüft worden It has been tested with the following harmonised standards Il a été testé à partir des normes harmonisées suivantes EN60335 1 2012 A11 2014 EN60335 2 41 2003 A1 2004 ...