background image

Mains connection

The  pump   is  electrically   connected   to   a  properly  installed   protective   contact   socket   with   a  mains
voltage of 230 V / 50 Hz.

Assembly

To avoid long suction lines and the resulting loss of performance, the pumps should be installed at or
below the water level if possible.

In the case of fixed pumping systems, the electric pump can be anchored on the ground. Use the
holes provided in the base plate for this.
The pumps must be installed in a well-ventilated, dry and flood-proof location.

Cable installation

The suction line must be protected against negative pressure and be installed approx. 30 cm
below the water level. This avoids the formation of whirls and the inevitably associated air
entry.

The line connections must be completely airtight. Bends and waves formed by the lines should
be avoided as far as possible.

The suction line should have a minimum gradient of 2% over its entire length so that no air
can remain inside the system.

The pressure line must have a diameter that is either equal to or larger than that of the pump
pressure connection.

The suction and pressure lines must never rest on the pump.

Make sure that all connections are tight so that the pump does not come into contact with
moisture and possibly be damaged.

We recommend the installation of a foot valve. When setting up, make sure that the pump is
not self-priming.

Operation

1.

Fill the system with water to find and repair any leaks.

2.

Open   any slide   valves  in   the  pressure   and   suction   lines and   check  whether  all  lines  are
connected.

3.

Let water run into the pump via the pool overflow / suction or fill the suction line and the pump
body completely with water. Not being self-priming, the pump must be completely filled before
operation to prevent it from running dry.

4.

Plug in the pump and check that the pump is circulating the water.

5.

If the pump is used above the pool water level, a foot valve must always be installed at the
beginning of the suction line so that the water does not run back from the suction into the pool
after the pump is switched off.

6.

If the motor does not start or if no water is transportend, please switch off the pump and check
whether there is any blockage inside the line system or inside the pump.

© by WilTec Wildanger Technik GmbH 

Item 50374–50377

Page 5 

http://www.WilTec.de
http://www.aoyue.eu

 

11 2020-1

http://www.teichtip.de

Summary of Contents for 50374

Page 1: ... operating instructions and safety information before using for the first time Technical changes reserved Due to further developments illustrations functioning steps and technical data can differ insignific antly Updating the documentation If you have suggestions for improvement or have found any irregularities please contact us ...

Page 2: ...uages can be found in our online shop via https www wiltec de docsearch Our postal address is WilTec Wildanger Technik GmbH Königsbenden 12 52249 Eschweiler Germany Do you wish to pick goods up Our pick up address is WilTec Wildanger Technik GmbH Königsbenden 28 52249 Eschweiler Germany To shorten the waiting time and allow for a rapid on site transaction we ask you to call us previously or placin...

Page 3: ...hey are supervised by a person responsible for their safety or have obtained instructions on how to use the device Children should be supervised to ensure that they do not play with the device Attention Perform a visual inspection of the device before each use Do not use the device if safety devices are damaged or worn Never override safety devices Only use the device in accordance with the intend...

Page 4: ...avoided Electrical connection The electrical connection is made to an earthed socket with 230 V 50 Hz Fusing at least 6 A The motor is protected against overloading or blocking by the built in thermal motor protection If the device is overheating the motor overheating protection automatically switches off the pump after it has cooled down the pump switches on again automatically Make sure that the...

Page 5: ...suction and pressure lines must never rest on the pump Make sure that all connections are tight so that the pump does not come into contact with moisture and possibly be damaged We recommend the installation of a foot valve When setting up make sure that the pump is not self priming Operation 1 Fill the system with water to find and repair any leaks 2 Open any slide valves in the pressure and suct...

Page 6: ...electric pumps do not require any special maintenance Please empty the dirt container regularly The pump body should be emptied before the cold season and if the system is not used for a longer period If the system is not used at all for a long period of time the pump must be cleaned rinsed thoroughly with clean tap water and stored in a dry and well ventilated place Residues of chlorine and other...

Page 7: ... bar Max 1 1 bar Temperature range 0 35 C liquid 0 35 C liquid 0 35 C liquid 0 35 C liquid Particle width 3 mm 3 mm 3 mm 3 mm Line connection 32 mm 38 mm 11 4 11 2 32 mm 38 mm 11 4 11 2 32 mm 38 mm 11 4 11 2 32 mm 38 mm 11 4 11 2 Protection class IPX4 IPX4 IPX4 IPX4 Cable length 1 5 m 1 5 m 1 5 m 1 5 m Weight 4 8 kg 5 6 kg 9 8 kg 10 8 kg by WilTec Wildanger Technik GmbH Item 50374 50377 Page 7 htt...

Page 8: ...s out that this article must not be treated as normal house hold waste but must be disposed to a recycling collec tion point for electronic and electrical waste equip ment By contributing to the correct disposal of this art icle you protect the environment and the health of your fellow men Environment and health are threatened by inappropriate disposal Materials recycling helps reduce the consumpt...

Page 9: ...enden EG Rats Richtlinien übereinstimmt This appliance is in conformity with the following European directives Cet appareil est conforme aux directives européennes 2014 35 EU Es ist nach folgenden harmonisierten Normen geprüft worden It has been tested with the following harmonised standards Il a été testé à partir des normes harmonisées suivantes EN60335 1 2012 A11 2014 EN60335 2 41 2003 A1 2004 ...

Reviews: