The operator is responsible for compliance with location-specific safety and installation
regulations. If necessary, ask a qualified electrician.
The user must take appropriate measures to prevent consequential damage caused by
flooding of rooms in the event of malfunctions on the device (e. g. installation of an alarm
system, reserve pump, etc.).
If the device fails, repairs should only be carried out by a qualified electrician.
The device must never run dry or be operated with the suction line fully closed.
The device must not be installed in the drinking water circuit.
We decline any liability for the consequences of improper installation, commissioning or
improper electrical installations.
Warning!
Read all safety warnings and instructions. Failure to follow the safety instructions and instructions can
result in electric shock, fire and / or serious injury.
Keep all safety notices and instructions for future use.
Resistance
The maximal temperature of the pumped liquid should not 35°C in continuous operation.
The pumping of aggressive liquids (acids, alkalis, silo seepage, etc.) as well as liquids with abrasive
substances (e. g. sand) must be avoided.
Electrical connection
•
The electrical connection is made to an earthed socket with 230 V ~ 50 Hz. Fusing at least
6 A.
•
The motor is protected against overloading or blocking by the built-in thermal motor protection.
If the device is overheating, the motor overheating protection automatically switches off the
pump; after it has cooled down, the pump switches on again automatically.
•
Make sure that the socket is adequately fused (min. 6 A) and works properly. Insert the pump
plug into the socket; the pump is then ready for operation.
Control measures before the first operation
Make sure that the power grid voltage and frequency and those of the pump (see type plate)
match.
Make sure that the pump shaft can rotate freely.
Fill the pump body with water by slightly unscrewing the corresponding self-priming cap.
Fill the system with water to find and repair any leaks.
Open any slide valves in the pressure and suction lines and check whether all lines are
connected.
Let water run into the pump via the pool overflow / suction or fill the suction line and the pump
body completely with water.
Never operate the pump dry.
The pumps are designed for clean water with a maximal temperature of 35°C; any other use should be
avoided.