Transportation and storage
6
WILO SE 2017-03
▪ Never allow unauthorised persons to perform work.
▪ Never operate the pump outside of the specified limits
of use.
▪ Never carry out unauthorised conversions.
▪ Use exclusively authorised accessories and authorised
spare parts.
▪ Never operate with phase angle control.
3.3
Operator responsibilities
The operator must:
▪ provide the installation and operating instructions in a
language which the personnel can understand.
▪ have all work carried out by qualified personnel only.
▪ make sure that personnel are relevantly trained for the
specified work.
▪ verify the area of responsibility and individual respons-
ibilities of personnel.
▪ train personnel with regards to the operating principles
of the system.
▪ eliminate risk from electrical current.
▪ equip hazardous components (extremely cold, ex-
tremely hot, rotating, etc.) with an on-site guard.
▪ have defective gaskets and connection pipes replaced.
▪ keep highly flammable materials at a safe distance from
the product.
All information that appears on the product must be
followed and kept permanently legible:
▪ Warnings
▪ Rating plate
▪ Direction of rotation arrow/symbol for direction of flow
▪ Identification of connections
This device can be used by children from 8 years of age
as well as people with reduced physical, sensory or
mental capacities or lack of experience and knowledge
if they are supervised or instructed on the safe use of
the device and they understand the dangers that can
occur. Children are not allowed to play with the device.
Cleaning and user maintenance is not allowed to be
carried out by children without supervision.
3.4
Safety instructions
Electrical current
DANGER
Electric shock!
The pump is operated electrically. An electric shock
may be a danger to life!
▪ Only allow work on electrical components to be carried
out by qualified electricians (according to EN 50110-1).
▪ Before all work deactivate power supply and guard
against accidental switch-on. Work on the control
module may only be started after 5 minutes have
elapsed, due to the dangerous residual contact voltage.
▪ Never open control module and never remove operator
controls.
▪ Operate pumps exclusively with intact components and
connection pipes.
Magnetic field
DANGER
Magnetic field!
The permanent magnet rotor inside the pump can
pose mortal danger for people with medical implants
(e.g pacemakers) during dismantling.
▪ Never remove the rotor.
Hot components
WARNING
Hot components!
Pump housing and glandless pump motor can get
hot and cause burns when touched.
▪ During operation only touch the control module.
▪ Allow the pump to cool down before commencing any
work.
▪ Keep highly flammable materials away.
4
Transportation and storage
4.1
Scope of delivery
▪ Pump
▪ 8x washer M12 (only flange-end pump)
▪ 8x washer M16 (only flange-end pump)
▪ 2x flat gasket (only threaded pipe union pump)
▪ Concise Installation and operating instructions
4.2
Accessories
Separately available:
▪ Thermal insulation shell
4.3
Transport inspection
Following delivery immediately check for damage and
integrity. Where necessary make a complaint immedi-
ately.
4.4
Transport and storage conditions
▪ Only carry by motor or pump housing ➜ Fig. 3.
▪ Store in original packaging.