Wilo Yonos MAXO-Z Installation And Operating Instructions Manual Download Page 17

Dortmund, 

_ Produits liés à l'énergie 2009/125/CE

Nach den Ökodesign-Anforderungen der Verordnung 641/2009 für Nassläufer-Umwälzpumpen , die durch die Verordnung 622/2012 geändert wird

This applies according to eco-design requirements of the regulation 641/2009 for glandless circulators amended by the regulation 622/2012
suivant les exigences d'éco-conception du règlement 641/2009 pour les circulateurs, amendé par le règlement 622/2012

_ Elektromagnetische Verträglichkeit-Richtlinie 2014/30/EU

_ Electromagnetic compatibility 2014/30/EU
_ Compabilité électromagnétique 2014/30/UE

_ Richtlinie energieverbrauchsrelevanter Produkte 2009/125/EG

_ Energy-related products 2009/125/EC

_ Machinery 2006/42/EC
_ Machines 2006/42/CE

und gemäss Anhang 1, §1.5.1, werden die Schutzziele der Niederspannungsrichtlinie 2014/35/EU eingehalten

and according to the annex 1, §1.5.1, comply with the safety objectives of the Low Voltage Directive 2014/35/EU
et, suivant l'annexe 1, §1.5.1, respectent les objectifs de sécurité de la Directive Basse Tension 2014/35/UE

N°2156057.01

(CE-A-S n°4178941)

H. HERCHENHEIN

Person authorized to compile the technical file is :
Personne autorisée à constituer le dossier technique est :

Senior Vice President - Group ITQ

EN 809+A1

sowie auch den Bestimmungen zu folgenden harmonisierten europäischen Normen :

comply also with the following relevant harmonized European standards :

sont également conformes aux dispositions des normes européennes harmonisées suivantes :

EN 61800-3+A1:2012

EN 60335-2-51

et aux législations nationales les transposant,

EU/EG KONFORMITÄTSERKLÄRUNG

EU/EC DECLARATION OF CONFORMITY

DECLARATION DE CONFORMITE UE/CE

Als Hersteller erklären wir unter unserer alleinigen Verantwortung, dass die Nassläufer-Umwälzpumpen der 

Baureihe,

We, manufacturer, declare under our sole responsability that these glandless circulating pump types of the series,

Nous, fabricant, déclarons sous notre seule responsabilité que les types de circulateurs de la série,

in der gelieferten Ausführung folgenden einschlägigen Bestimmungen entsprechen :

In their delivered state comply with the following relevant directives : 

dans leur état de livraison sont conformes aux dispositions des directives suivantes :

und entsprechender nationaler Gesetzgebung,

_ Maschinenrichtlinie 2006/42/EG

O

ri

gi

na

l-

er

kl

är

un

O

ri

gi

na

l d

ec

la

ra

tio

D

éc

la

ra

tio

or

ig

in

al

e

WILO SE

Nortkirchenstra

β

e 100

44263 Dortmund - Germany

F_

G

Q

_0

13

-2

1

(Die Seriennummer ist auf dem Typenschild des Produktes nach Punkten b) & c) von §1.7.4.2 
und §1.7.3 des Anhanges I der Maschinenrichtlinie angegeben. / The serial number is marked 
on the product site plate according to points b) & c) of §1.7.4.2 and §1.7.3 of the annex I of 
the Machinery directive. / Le numéro de série est inscrit sur la plaque signalétique du produit 
en accord avec les points b) & c) du §1.7.4.2 et du §1.7.3 de l’annexe I de la Directive 
Machines.)

Yonos MAXO-Z …

Division HVAC
Quality Manager - PBU Circulating Pumps
WILO SE
Nortkirchenstra

β

e 100

D-44263 Dortmund

and with the relevant national legislation,

EN 16297-2

Bevollmächtigter für die Zusammenstellung der technischen Unterlagen ist:

EN 16297-1

Digital unterschrieben 

von Holger Herchenhein 

Datum: 2017.02.17 

15:24:34 +01'00'

Summary of Contents for Yonos MAXO-Z

Page 1: ...Pioneering for You Wilo Yonos MAXO Z 2189869 Ed 01 2017 03 en Installation and operating instructions...

Page 2: ...delivery 6 4 2 Accessories 6 4 3 Transport inspection 6 4 4 Transport and storage conditions 6 4 5 Transport 7 5 Installation 7 5 1 Personnel requisition 7 5 2 Safety during installation 7 5 3 Prepari...

Page 3: ...ions Wilo Yonos MAXO Z 3 8 2 Safety during troubleshooting 14 8 3 Error table 15 8 4 Fault signals 15 8 5 Warning signals 15 9 Spare parts 16 10 Disposal 16 10 1 Information on the collection of used...

Page 4: ...ful information on handling the product Symbols These instructions use the following symbols General danger symbol Danger of electric voltage Warning of hot surfaces Warning of magnetic fields Notes 1...

Page 5: ...For further instructions see rating plate and catalogue 2 5 Min inlet pressure Nominal dia meter Fluid temperature 0 to 50 C up to 95 C up to 110 C RP 1 0 3 bar 1 0 bar 1 6 bar RP 1 0 3 bar 1 0 bar 1...

Page 6: ...owed to play with the device Cleaning and user maintenance is not allowed to be carried out by children without supervision 3 4 Safety instructions Electrical current DANGER Electric shock The pump is...

Page 7: ...crews observe the following 1 Close shut off device or drain unit 2 Cool down the unit completely 5 3 Preparing the installation 1 Complete all welding and brazing tasks 2 Flush unit 3 Provide shut of...

Page 8: ...65 Screw diameter M 12 M 12 M 12 M 12 Strength class 4 6 4 6 4 6 4 6 Tightening torque 40 Nm 40 Nm 40 Nm 40 Nm Screw length 55 mm 55 m m 60 m m 60 mm Flange end pump PN 10 DN 32 DN 40 DN 50 DN 65 Scre...

Page 9: ...ing must point in the direction of flow Fig 8 Pump installation 3 Screw together flange with suitable screws and the supplied washers Observe aforementioned tightening torques Fig 9 Opening shut off d...

Page 10: ...the pump Fig 11 Pump installation 3 Insert the supplied flat gaskets into the pump 4 Screw together the pump with the union nuts In do ing so hold it exclusively against the flat faces on the pump hou...

Page 11: ...ump deactivate a pulse of the voltage for example phase angle control Switching the pump via triacs solid state relays must be examined on a case by case basis During deactivation with on site power r...

Page 12: ...ve fault signal line are led together through a 5 wire cable Do not connect SSM pipe to protective low voltage Use 5 x 1 5 mm cable Connection minimum permitted 12 V DC 10 mA maximum permitted 250 V A...

Page 13: ...ts 6 Flip open the plug Fig 18 Connect 7 Remove the elastic fastener from the cable ducts using a small screwdriver 8 Guide the pipes through the cable ducts to the connection sockets Fig 19 Connect 9...

Page 14: ...ressure setpoint H Recommended for systems with balancing valves 7 4 Adjust operating mode and pump output Factory setting The pumps are delivered in control mode p c The re quired delivery head is pr...

Page 15: ...return valve if necessary E10 Blocking Rotor blocked Contact cus tomer service E212 Overload Slow motor Contact cus tomer service E23 Short circuit Motor current too high Contact cus tomer service No...

Page 16: ...ar on the product the packaging or the accompanying documentation It means that the electrical and electronic products in question must not be dis posed of along with domestic waste To ensure proper h...

Page 17: ...0335 2 51 et aux l gislations nationales les transposant EU EG KONFORMIT TSERKL RUNG EU EC DECLARATION OF CONFORMITY DECLARATION DE CONFORMITE UE CE Als Hersteller erkl ren wir unter unserer alleinige...

Page 18: ...kuutuksessa kuvatut tuotteet ovat seuraavien eurooppalaisten direktiivien m r ysten sek niihin sovellettavien kansallisten lakiasetusten mukaisia WILO SE ndearbha onn an cur s os ar na t irg at i r it...

Page 19: ...2014 30 WE Produkt w zwi zanych z energi 2009 125 WE WILO SE WILO SE estne prehlasuje e v robky ktor s predmetom tejto deklar cie s v s lade s po iadavkami nasleduj cich eur pskych direkt v a odpoveda...

Page 20: ...HJUDWH 0 7 ZLOR LWDOLD ZLOR LW D DNKVWDQ 2 HQWUDO VLD OPDW 7 LQIR ZLOR N RUHD 2 3XPSV WG DQJVHR XVDQ 7 ZLOR ZLOR FR NU DWYLD 2 DOWLF 6 5LJD 7 LQIR ZLOR OY HEDQRQ 2 121 6 5 GHLGHK HEDQRQ 7 LQIR ZLOR FR...

Page 21: ...Pioneering for You WILO SE Nortkirchenstr 100 44263 Dortmund Germany T 49 0 231 4102 0 T 49 0 231 4102 7363 wilo wilo com www wilo com...

Reviews: