3.5. Type key
Example: Wilo-Rexa
FIT V06DA-110/EAD1-2-T0015-540-P
FIT
Series
V
Impeller shape
V = vortex impeller
06
Pressure connection size
05 = DN 50
06 = DN 65/80
08 = DN 80
D
Hydraulic version
D = suction side drilled acc. to DIN
N = suction side drilled acc. to North American
Standard (ANSI)
A
"Hydraulic" material version
A = standard type
110
Type of hydraulics
E
Motor version
E = dry motor
R = reduced-power glanded motor
A
"Motor" material version
A = standard type
D
Seal version
D = 2 independent mechanical shaft seals
1
IE efficiency class, e.g.: 1 = IE1 (based on
IEC 6003430)
-
not Ex-rated
2
Number of poles
T
Mains connection version
M = 1~
T = 3~
0015
/10 = rated power P
2
in kW
5
Frequency
5 = 50 Hz
6 = 60 Hz
40
Key for rated voltage
P
Additional electrical equipment
O = with bare cable end
A = with float switch and plug
P = with plug
3.6. Scope of delivery
•
Pump with 10 m cable
• Single-phase version with
• Shockproof plug
•
Float switch and shockproof plug
•
Three-phase version with
• bare cable end
•
Float switch and CEE plug
• Installation and operating instructions
3.7. Accessories
• Cable lengths up to 30 m (single-phase version)
or 50 m (three-phase version) in fixed length
increments of 10 m
• Suspension unit
• Pump foot
•
External pencil electrode for sealing chamber
control
•
Level controls
•
Fixing accessories and chains
• Switchgears, relays and plugs
4. Transport and storage
4.1. Delivery
On delivery, check immediately that the ship
-
ment is complete and undamaged. If any parts
are damaged or missing, the transport company
or the manufacturer must be notified on the day
of delivery. Claims made after this date cannot be
recognised. Damage to parts must be noted on
the freight documentation.
4.2. Transport
Only the appropriate and approved fastening
devices, transportation and lifting equipment may
be used. These must have sufficient load-bearing
capacity to ensure that the pump can be trans-
ported safely. If chains are used they must be
secured against slipping.
The personnel must be qualified for the tasks and
must follow all applicable national safety regula-
tions during the work.
The pump is delivered by the manufacturer or
shipping agency in suitable packaging. This nor
-
mally precludes the possibility of damage occur-
ring during transport and storage. The packaging
should be stored in a safe place for reuse if the
product is frequently used at different locations.
4.3. Storage
Newly supplied pumps are prepared so that they
can be stored for at least 1 year. The pump should
be cleaned thoroughly before it is put into tem-
porary storage.
The following should be taken into consideration
for storage:
•
Place the pump on a firm surface and secure it
against slipping and falling over. Submersible
sewage pumps are stored horizontally.
DANGER due to falling over!
Never set the pump down if unsecured. If the
pump falls over, this may lead to injuries!
•
Our pumps can be stored to max. 15 °C. The stor
-
age area must be dry. We recommend a frost-pro
-
tected room for storage with a temperature
between 5 °C and 25 °C.
•
The pump is not allowed to be stored in rooms
in which welding work is carried out, because
the resulting gases or radiation can damage the
elastomer components and coating.
• Suction and pressure connections must be sealed
securely to prevent contamination getting in.
• All power supply cables must be protected
against kinking, damage and moisture ingress.