English
Installation and operating instructions Wilo-SiClean Comfort
29
Immediately on conclusion of the work, all safety and protective
devices must be put back in position and/or recommissioned.
2.7
Unauthorised modification and
manufacture of spare parts
Unauthorised modification and manufacture of spare parts will impair
the safety of the product/personnel and will make void the manufac-
turer's declarations regarding safety.
Modifications to the product are only permissible after consultation
with the manufacturer. Original spare parts and accessories author-
ised by the manufacturer ensure safety. The use of other parts will
absolve us of liability for consequential events.
2.8
Improper use
The operating safety of the supplied product is only guaranteed for
conventional use in accordance with Section 4 of the operating
instructions. The limit values must on no account fall under or exceed
those specified in the catalogue/data sheet.
3
Transport and interim storage
When the product is delivered, check it for any damage in transit. If
any defect is found, inform the delivery company (forwarding agent).
The equipment must be transported by means of authorised load
devices.
Before installation, the product must be kept dry, frost-free and pro-
tected from mechanical damage.
CAUTION! Risk of property damage!
Improper transport and interim storage can cause damage to the
product.
• The product must not be exposed to temperatures outside the
range between -10°C and +50°C.
Wilo-SiClean Comfort is supplied on a pallet, it is protected from
moisture and dust with a transparent plastic cover.
3.1
Transport for installation/removal
purposes
WARNING! Danger of personal injury!
Improper transport can lead to personal injury.
• The stability of the load must be ensured.
• The handling should be done by skilled staff and with authorised
equipment.
• Transport straps must be secured to the existing transport lugs.
4
Intended use
Purpose
The basic function of Wilo-SiClean Comfort is to protect heating sys-
tems against particles and sludge formation through continuous
removal of suspended matter.
Fields of application
It may be used for:
• Hot-water heating systems
• Heating/air-conditioning systems
Restrictions
Typical installation locations are technical rooms within the building
with other domestic installations. It is not intended to install the sys-
tem directly in rooms used for residential or working purposes.
Outdoor installation is not permitted for this series.
Summary of Contents for SiClean Comfort 12
Page 2: ...Fig 1 1 10 11 5 6 4B 4A 3 2 8 9 7 Fig 2 5 4 1 2 3...
Page 3: ...Fig 3 3 6 2 4 5 1 1...
Page 4: ...Fig 4...