5.2 Technical data
Maximum utilisation pressure
Pump housing
16, 25 or 30 bar depending on the model
Maximum suction pressure
10 bar
Notice: the actual input pressure (P input) + the pressure at zero delivery
rate (P zero delivery rate) must always be lower than the maximum au
-
thorised operating pressure (P max). If the maximum authorised operat
-
ing pressure is exceeded, the mechanical seal and the roller bearing can
be damaged or their life span reduced.
P input + P zero delivery rate ≤ Pmax
Refer to the pump plate for the maximum operating pressure: Pmax
Temperature range
Fluid temperature
-30 °C to +120 °C
-15 °C to + 90 °C (FKM version for O’ring and mechanical seal)
Ambient temperature
-15 °C to +50 °C On request for other temperature
Storage temperature min./max.
-20 °C to +60 °C
Electrical data
Motor efficiency
IE5
Motor protection rating
IP55
Insulation class
155 (F)
Frequency
See motor plate
Power supply voltage
Power (kW)
11
15
18.5
22
400 V (±10 %) 50 Hz
380 V (±10 %) 60 Hz
480 V (±10 %) 60 Hz
Types of supported power supplies
TN, TT
Other characteristics
Ambient humidity
< 90 % without condensation
Altitude
< 1000 m (> 1000 m on request)
Max. suction height
Depending on NPSH of the pump
Noise Level Lp dB(A), ref. 20 μPa at 1 m,
BEP tolerance 0-3dB(A)
Power (kW)
11
15
18.5
22
79
Power supply cable cross section
diameter (cable equipped
with 4 wires) mm
2
Power (kW)
11
15
18.5
22
4 – 6
6 – 10
10 – 16
- Electromagnetic compatibility
(*)
• Residential emission –
1st environment:
PN-EN 61800-3
• Industrial interference resistance –
2nd environment:
PN-EN 61800-3
(*) In the frequency range between 600
MHz and 1
GHz,
the display or the pressure indication in the display
might be disturbed in the exceptional case of the direct
vicinity (<1
m from the electronic module) of radio
transmission installations, transmitters or similar devic-
es working in this frequency range. The operation of the
pump is not affected at any time.
-
Outline and connection dimensions (Fig. 4).
5.3 Scope of delivery
• High-pressure multistage centrifugal pump.
• Operating manual.
Summary of Contents for Helix VE 11kW-IE5
Page 2: ...Fig 1 ...
Page 3: ...Fig 2 HELIX VE 10 16 ...
Page 4: ...Fig 2 HELIX VE 22 36 52 ...
Page 8: ...Fig 9 HELIX VE 22 36 52 Fig 8 x2 x4 ...
Page 9: ...Fig A1 1 1 ...
Page 10: ...2 2 4 4 3 3 Fig 2D Fig 3D 4 4 3 3 2 2 Fig 4D 3 3 4 4 2 2 ...
Page 11: ...en Installation and operating instructions 12 ...
Page 42: ......
Page 43: ......
Page 44: ......
Page 45: ......
Page 46: ......
Page 47: ......