Installation and operating instructions Wilo Motor T 12 ... 72 + EMU FA, Rexa SUPRA, Rexa SOLID
35
ƒ
Swap the connections of two windings (e.g. U1/V1 and U2/V2) for star-delta activa-
tion motors.
7.4
Operation in an explosive atmo-
sphere
DANGER
Risk of explosion due to flying sparks in the hydraulics!
During operation the hydraulics must be flooded (completely filled with the fluid). If
the volume flow is interrupted or the hydraulics emerges, air cushions can form in
the hydraulics. If this happens, there is a risk of explosion, e.g. flying sparks due to
static charge! Dry-running protection must ensure that the pump is deactivated at
the appropriate level.
Overview of standard motors
T 12
T 13
T 17
T 17.2
T 20
T 20.1
T 24
T 30
T 34
T 42
T 49
T 50
T 50.1
T 56
T 63.1/T 63.2
T 72
ATEX approval
o
o
o
o
o
o
o
o
o
o
−
−
o
o
o
−
FM approval
o
o
o
o
o
o
o
o
o
o
o
−
o
o
o
−
CSA-Ex approval
o
o
o
o
o
−
o
o
o
−
−
−
−
−
−
−
Key
− = not available/possible, o = optional, • = as standard
Overview of IE3 motors (derived from IEC 60034)
T 17 ...-E3
T 17.2 ...-E3
T 20.1 ...-E3
T 24 ...-E3
T 30 ...-E3
T 34 ...-E3
T 42 ...-E3
T 50.1 ...-E3
T 57.1 ...-E3
T 63.1 ...-E3
T 63.2 ...-E3
ATEX approval
o
o
o
o
o
o
o
o
o
o
o
FM approval
−
−
−
−
−
−
−
−
−
−
−
CSA-Ex approval
−
−
−
−
−
−
−
−
−
−
−
Key
− = not available/possible, o = optional, • = as standard
For use in explosive atmospheres, the pump must be marked as follows on the rating
plate:
ƒ
“Ex” symbol of the corresponding approval
ƒ
Ex classification
For the relevant requirements, refer to the explosion protection chapter in the ap-
pendix of these installation and operating instructions!
ATEX approval
The pumps are suitable for operation in potentially explosive atmospheres:
ƒ
Device group: II
ƒ
Category: 2, zone 1 and zone 2
These pumps must not be used in zone 0!
FM approval
The pumps are suitable for operation in potentially explosive atmospheres:
ƒ
Protection class: Explosionproof
ƒ
Category: Class I, Division 1