en
Appendix
62
WILO SE 2019-01
13.3.6
Maintenance and repair
ƒ
Carry out maintenance tasks according to the regulations.
ƒ
Only carry out maintenance tasks mentioned in these installation and operating in-
structions.
ƒ
The spark-proof gaps may
only
be repaired according to the manufacturer’s design
specifications. It is
not
permitted to carry out repairs according to the values in
tables 1 and 2 of DIN EN 60079-1.
ƒ
Only use screw plugs as stipulated by the manufacturer, that at least correspond to a
strength class of 600 N/mm² (38.85 long tons-force/inch²).
13.3.6.1 Repair of housing coating
The paint layer can become electrostatically charged in case of thicker
coats.
DANGER! Risk of explosion! In explosive atmospheres, a discharge can cause
an explosion!
If the housing coating has to be repaired, the maximum coat thickness is 2 mm
(0.08 in)!
13.3.6.2 Changing the mechanical seal
Changing the seal on the fluid and motor side is strictly prohibited!
13.3.6.3 Replacing the connection cable
Changing the connection cable is strictly prohibited!
Summary of Contents for EMU FA
Page 2: ......