7.2.2 Electric motor connection

The ElectronicControl shall be connected to the pump motor terminal according 
to the wiring diagrams Fig 5 or Fig 6. 

7.2.3 Electric connection of a dry running protection

The ElectronicControl can be provided with an additional dry running protection 
such as dry contact (flow switch or others). See Fig. 7 for the connection.

8 Commissioning

CAUTION! Risk of health hazards!
Our ElectronicControl is tested in water. If any water remains inside it, for 
hygiene reasons it is recommended to rinse it before any use in the potable 
water network.

When switching on the ElectronicControl immediately carries out a diagnosis 
that lasts 10 seconds and will display the type and version. The led 

 is on.

In case of a pump at suction, the priming of the pump shall be done manually 
(manual mode). During the priming step (see operating instruction of the pump) 
it may drive the pump at its maximum speed. 
As soon as the pump is priming on, the ElectronicControl can be switched on 
Automatic mode.

9 Maintenance

Maintenance and repairs shall only be carried out by qualified personnel!
DANGER! Risk of death!
When working on electrical equipments, there is a risk of fatal injury due to 
electrical shocks.
Before any maintenance or repair works, switch off the unit/station (no volt-
age) and be sure it cannot be switched on again without any control. Gener-
ally only a qualified electrician is authorized to repair damaged connection 
cables.

Before a frost period it is necessary to drain the ElectronicControl. 
Every 6 month check the right operating of the installation: 

• the pressure of the bladder tank, 
• the tightness of the connections and
• the proper closing of the valve.

1_Wilo-ElectronicControl.book  Seite 26  Montag, 11. Juli 2011  3:14 15

Summary of Contents for Electronic Control MM6

Page 1: ...de montage et de mise en service NL Inbouw en bedieningsvoorschriften E Instrucciones de instalaci n y funcionamiento I Istruzioni di montaggio uso e manutenzione GR RUS Wilo ElectronicControl 4 159 7...

Page 2: ...Fig 1 Fig 2 1_Wilo ElectronicControl book Seite 2 Montag 11 Juli 2011 3 14 15...

Page 3: ...Fig 3 Fig 4 1_Wilo ElectronicControl book Seite 3 Montag 11 Juli 2011 3 14 15...

Page 4: ...Fig 5 Fig 6 Fig 7 1_Wilo ElectronicControl book Seite 4 Montag 11 Juli 2011 3 14 15...

Page 5: ...f the EC declaration of conformity is a component of this installation and operating instruction If the ranges mentioned in this instruction are subject to changes without any prior approval this decl...

Page 6: ...ects Property damage 2 4 Safety instructions for the operator The existing directives for accident prevention must be adhered to Danger from electrical current must be eliminated Local directives or g...

Page 7: ...d those specified in the catalogue or data sheet 3 Transport and storage The product is delivered in a cardboard box It is protected against moisture and dust As soon as the product arrives immediatel...

Page 8: ...f the ElectronicControl 1 230V T Electrical supply of the motor T 3 230V M 1 230V 6 Maximal current delivered in A 5 2 Technical data Maximum operating pressure 15 bar Setting range 0 5 up to 12 bars...

Page 9: ...03 Cable gland of the dry running protection 04 Cable gland of the serial communication as option 05 Suction 06 Discharge 07 User interface Pos Description of the components 01 Pump 02 ElectronicContr...

Page 10: ...10 2 dry running over currents too high water temperatures frost short circuits over voltages Under voltages In case of defect such as dry running overvoltage the led blinks and the ElectronicControl...

Page 11: ...the next parameter is displayed on the screen With the push button you exit SETTINGS no saving of the last change or HISTORIC menu and go back to STANDARD display mode or SERVICE NOTE The data are sav...

Page 12: ...essure set ting in the installation START DELTA P 0 3 BAR Start delta P Define the starting pressure as starting pressure setpoint pressure start delta P TIME BEFORE STOP 5 S TIME BEFORE STOP Time set...

Page 13: ...one by a qualified electrician and in compliance with the regulations in force Follow all accident prevention regulations Before installation and electrical connection switch off the product station s...

Page 14: ...tronicControl A blad der tank over 2 liter volume Fig 2 Pos 4 shall allow an optimal regulation of the pressure inside the installation A pre setting pressure 0 5 bars lower than the set point pressur...

Page 15: ...pump at suction the priming of the pump shall be done manually manual mode During the priming step see operating instruction of the pump it may drive the pump at its maximum speed As soon as the pump...

Page 16: ...T MOTOR Motor supply stop Check the motor winding Check the supply cables Check the state of the 20A fuses Fig 4 Pos 4 E040 P SENSOR DEFFECT The ElectronicControl stops Q Contact the technical service...

Page 17: ...To avoid queries and order errors please supply all data on the name plate with every order Subject to change without prior notice E004 LOW VOLTAGE If the ElectronicControl detects an under voltage i...

Reviews: