English
20
4 Products and accessories
4.1 Description (see Fig. 1-9):
1 : Foot valve with suction strainer (maximum
free-flowing cross-section 1 mm)
2 : Stop valve; on suction side
3 : Stop valve; on the pressure side
4 : Non-return valve
5 : Inlet/bleeder screw
6 : Drainage screw
7 : Pipe bracket
8 : Suction strainer
9 : Replenishment reservoir
10 : Tap water network
11 : Switch, switch amplifier with fuses
12 : Cock
13 : Pedestal
14 : Pressure sensor
15 : Diaphragm pressure vessel
16 : Gate valve for diaphragm pressure vessel
17 : Red LED
18 : Green LED
19 : Potentiometer
20 : Connection terminal
21 : Protection against low water level
HA : Maximum suction head
HC : Minimum suction head
4.2 The pump
Horizontal centrifugal pump.
Multistage, not self-priming.
Suction/outlet openings with thread.
Axial suction, radial outlet upwards.
Sealing on shaft passage by means of standard
mechanical seal.
4.3 The motor with frequency converter
Three-phase AC motor, two-pole, with frequency
converter.
Protection class: IP 54.
Insulation class: F
4.4 Accessories (optional)
• Suction kit
• Shut-off device
• Diaphragm pressure vessel
• Tank
• Non-return valve
• Foot valve with suction strainer
• Compensator
• Protection against low water level
(potable water network)
(see Fig. 5, Pos. 21)
• Pressure sensor control kit (sensor precision:
#
1%; utilisation between 30% and 100% of the
reading range).
5 Installation
Two types:
•
see Fig 1: Suction mode.
•
see Fig. 2: Pressure operation from replenish-
ment vessel
(Pos. 9) or potable water network
(Pos. 10).
5.1 Installation
Install the pump at a readily accessible location
which is protected against external influences
(excessive rain or sunlight, frost) and which is as
near as possible to the extraction point.
Place the pump on a pedestal
(Pos. 13) or directly
on a smooth, level base. Fixation of the pump
with 2 holes for Ø M8 bolts.
Note that the height of the installation
location and the temperature of the
fluid will diminish the suction capacity
of the pump.
Installation should be carried out in
pressure operation when temperatures
exceed 80°C.
5.2 Pipe connections
The installation must be sufficient for
the pressure that the pump generates
at maximum frequency and zero flow
volume.
- Connection with spiral-reinforced flexible hoses
or rigid pipe.
-
Seal the pipe connections well with suitable
products. No air is permitted to enter the suc-
tion line; lay the suction line with a continuous
rise (2%) (see Fig. 1).
- In the case of rigid pipes, take care to ensure that
the weight of the lines is not borne by the pump
alone. Utilise supports and/or pipe brackets
(see
Figs. 1 + 2, Pos. 7).
Pump
MHIE
type 200
400 800
Suction
1"1/4 -
1"1/2 -
opening
1"- (26-34)
(33-42)
(40-49)
Outlet
1" -
1"1/4 -
opening
1" - (26-34)
(26-34)
(33-42)
Pipe connections
Height Height loss
Temperature Height loss
meter
0.0
0 m 0.00 mCL
20°C
0.20 mCL
500 m 0.60 mCL
30°C
0.40 mCL
1000 m 1.15 mCL
40°C
0.70 mCL
50°C
1.20 mCL
60°C
1.90 mCL
70°C
3.10 mCL
80°C
4.70 mCL
90°C
7.10 mCL
100°C
10.30 mCL
110°C
14.70 mCL
120°C
20.50 mCL
ATTENTION!
ATTENTION!
ATTENTION!
Frequency
50 Hz
60 Hz
Voltages 1~230 V (±10%)
1~220 V (±6%)
Operational voltages and frequencies
WILO SE 04/2016