  1 General

 1.1 Applications

Pumps for pumping clear liquids in the residential 

sector, in agriculture and in industry. Intake from 

wells, springs, water streams, ponds ... not to be 

used with Abyssinian wells (driven wells).

 

1.2  Technical data

 

•  Maximum operating pressure: 

10 bar

 

•  Minimum intake pressure: 

  6 bar

 

•  Temperature range:

-  Version with seals and inserts made of EPDM*:  

-15° to +110°C

-  Version with seals and inserts made of VITON*:  

-15° to +90°C

 

•   Suction  head:   

depending on the Net Positive Suction Head 

(NPSH) of the pump

 

•   Ambient temperature (standard):  

+40°C (in cases of higher temperatures, please  

consult Wilo after-sales service)

 

•  Sound pressure level 50/60Hz 0/+3 dB(A): 66

*Application in potable water sector: 

WRAS: English standard, 

KTW: German standard.

  2 Safety

These Installation and operating instructions con-

tain basic information which must be adhered to 

during installation and commissioning. For this 

reason, these Installation and operating instruc-

tions must, without fail, be read by the service 

technician and the responsible operator before 

installation and commissioning. It is not only the 

general safety instructions which are listed here 

under the main heading of Safety which must be 

complied with, but rather also the special safety 

instructions which are listed under the following 

main headings.

  2.1   Identification of notes in the Installation and 

operating instructions

The safety instructions contained in these 

Installation and operating instructions which, if 

they are not observed, could endanger person-

nel, are specially marked with the General danger 

symbol,

and with 

in cases of warnings against electrical voltage. 
 
The word 

is included with safety instructions which, if they 
are not observed, could endanger the installation 
and its function.

  2.2  Personnel qualifications

The personnel responsible for installation must 

be in possession of the respective qualifications 

required for this work.

  2.3   Danger in the event of nonobservance of the 

safety instructions

 The failure to observe the safety instructions 

could result in dangers to personnel and pump/

installation. Nonobservance of the safety instruc-

tions can result in the loss of any claims to dam-

ages.

In particular, the failure to observe these instruc-

tions could lead to the following hazards:

 

•   Failure of important functions of the pump/instal-

lation.

 

•   Hazards to personnel resulting from electrical, 

mechanical or bacteriological actions,

 

•   Property  damage.

  2.4  Safety instructions for the operator

The existing regulations regarding accident pre-

vention are to be complied with.

Hazards connected with electrical energy are to 

be excluded. The regulations of the VDE (Verband 

der Elektrotechnik Elektronik und Informations- 

technik e.V.) and of the local energy supply com-

panies are to be complied with.

  2.5   Safety instructions for inspection and installa-

tion work

It is the responsibility of the operator to ensure 

that all inspection and installation work is carried 

out by authorised and qualified professionals 

who have acquired sufficient information from a 

detailed study of the Installation and operating 

instructions.

As a fundamental principle, work may only be car-

ried out on the pump/installation when it/they are 

at a standstill.

  2.6   Customer’s own conversions and spare parts 

manufacture

Modifications to the pump/installation are not 

permitted except after consultation with the 

manufacturer. The use of original spare parts and 

manufacturer-authorised accessories promotes 

safety. The use of other parts could lead to the 

cancellation of liability for the results of such 

substitutions.

  2.7  Improper use

The operating safety of the supplied pump/instal-

lation is only guaranteed for conventional use 

in accordance with Section 1 of the Installation 

and operating instructions. It is not permitted to 

exceed or fail to meet the limit values specified 

in the catalogue/data sheet under any circum-

stances.

  3  Transport, handling and storage

The pump/installation is to be checked at once 

upon delivery for any damage that may have 

occurred in transit. If any damages are found, then 

they are to be reported to the transport company 

immediately within the time periods specified.

If the material is to be installed later, 

then it must be stored in a dry location. 

The material must be protected against 

impact shocks and all external influen-

ces (moisture, frost, etc.).

Handle the pump carefully so that the geometry 

and alignment of the installation are not altered.

The pump is not permitted under any 

circumstances to be raised on the fre-

quency converter.

ATTENTION!

ATTENTION!

ATTENTION!

WILO SE 04/2016

Summary of Contents for Economy MHIE 1 Series

Page 1: ...d Betriebsanleitung en Installation and operating instructions fr Notice de montage et de mise en service nl Inbouw en bedieningsvoorschriften es Instrucciones de instalaci n y funcionamiento it Istru...

Page 2: ...Fig 1 Fig 3 Fig 2 Fig 4 Fig 5 or ou or ou...

Page 3: ...Fig 6 Fig 7 Fig 8 or ou or ou...

Page 4: ...Fig 9 Fig 10...

Page 5: ...he failure to observe these instruc tions could lead to the following hazards Failure of important functions of the pump instal lation Hazards to personnel resulting from electrical mechanical or bact...

Page 6: ...table water network Pos 10 5 1 Installation Install the pump at a readily accessible location which is protected against external influences excessive rain or sunlight frost and which is as near as po...

Page 7: ...standard specifications The electrical properties frequency voltage nominal current of the motor frequency convert er are indicated on the name plate of the motor of the pump A check is to be made as...

Page 8: ...r of the frequency converter Mains connection Connect three lines of the cable to the 3 connection terminals of the board Phase Neutral Earth Connecting the inputs outputs 3 operating modes exist see...

Page 9: ...0 V 24 V 24 V 2 3 4 5 6 7 8 9 10 11 12 13 14 0 V 4 20 mA 24 V 0 V 0 10 V 24 V 2 Connection of the potentiometer Connection terminals Inputs outputs of the frequency converter Diagram Adjusting the se...

Page 10: ...ble connections It is possible to start or stop the pump with the external control potential free contact this function takes precedence over the other functions This external control can be removed b...

Page 11: ...3 1 6 3 1 4 3 1 7 3 1 5 4 ATTENTION Operating modes Mode 1 Mode 3 0 20 mA Mode 3 0 10 V Mode 2 PI control sensor 4 20 mA Mode 2 PI control sensor 0 10 V Mode 2 PI control sensor 4 20 mA External contr...

Page 12: ...0 V Input voltage V Pressure in of the sensor measurement range 100 0 2 20 Setpoint 0 20 mA Range in which the frequency converter stops Input current level mA Pressure in of the sensor measurement ra...

Page 13: ...instruction manual for the pressure boosting sys tem During normal operation the status of the LEDs is as follows see Fig 9 Pos 17 18 6 2 Preparatory flushing Because our pumps are hydraulically test...

Page 14: ...on the pump shield 7 Maintenance The pump s must be de energised and all non authorised restarts must be pre vented before any maintenance work is done Never undertake maintenance work while the pump...

Page 15: ...ontact your local professional tradesmen or the Wilo after sales service in your vicinity ATTENTION Display Frequency converter beha viour Fault possible causes Elimination Green LED Red LED Reaction...

Page 16: ...intained b The suction line has a smaller circ umference than that of the pump c Suction strainer and suction line are partially blocked a Check correct setting of the nominal values setpoints matchin...

Page 17: ...any Die Seriennummer ist auf dem Typenschild des Produktes nach Punkten b c von 1 7 4 2 und 1 7 3 des Anhanges I der Maschinenrichtlinie angegeben The serial number is marked on the product site plate...

Page 18: ...k nemzeti jogrendbe t ltetett rendelkez seinek WILO SE vakuuttaa ett t ss vakuutuksessa kuvatut tuotteet ovat seuraavien eurooppalaisten direktiivien m r ysten sek niihin sovellettavien kansallisten l...

Page 19: ...4 30 ES Maszyn 2006 42 WE Kompatybilno ci Elektromagnetycznej 2014 30 WE WILO SE WILO SE estne prehlasuje e v robky ktor s predmetom tejto deklar cie s v s lade s po iadavkami nasleduj cich eur pskych...

Page 20: ...2785961 info wilo kz Korea WILO Pumps Ltd 618 220 Gangseo Busan T 82 51 950 8000 wilo wilo co kr Latvia WILO Baltic SIA 1019 Riga T 371 6714 5229 info wilo lv Lebanon WILO LEBANON SARL Jdeideh 1202 2...

Page 21: ...Pioneering for You WILO SE Nortkirchenstra e 100 D 44263 Dortmund Germany T 49 0 231 4102 0 F 49 0 231 4102 7363 wilo wilo com www wilo com...

Reviews: