3 Transport and interim storage

The system and individual components are delivered on a pallet.
Immediately after receiving the product:

• Check the product for damage in transit
• In the event of damage in transit, take the necessary steps with the forwarding agent 

within the respective time limits. 

CAUTION! Risk of property damage!
Incorrect transport and interim storage can cause damage to the product.

• Only transport the product on the pallet and only use approved handling equipment.
• Make sure the product remains stable and does not suffer any mechanical damage dur-

ing transport.

• Prior to installation, store the product on the pallet in such a manner that it remains dry 

and frost-proof and is not exposed to direct sunlight.

• Do not stack.

4 Intended  use

The DrainLift XL sewage lifting unit is an automatically operating wastewater lifting unit in 
accordance with EN 12050-1 for backup-free drainage of sewage that does and does not 
contain faeces and that originates from building discharge points below the backflow level.
The unit is only suitable for domestic sewage as defined in EN 12056-1. According to DIN 
1986-3 [in Germany], no explosives or harmful substances may be introduced in high con-
centrations, such as solid substances, debris, ashes, garbage, sand, plaster, cement, lime, 
mortar, fibrous materials, textiles, paper towels, diapers, cardboard, coarse paper, syn-
thetic resins, tar, kitchen waste, greases, oils, slaughterhouse waste, disposal of slaugh-
tered animals and animal waste (liquid manure, etc.), toxic, aggressive and corrosive 
substances, such as heavy metals, biocides, pesticides, acids, bases, salts, cleaning agents 
and disinfectants, dish-washing or laundry detergents, and such which have a high degree 
of foam formation or swimming-pool water.
A grease trap should to be provided if greasy sewage accumulates.
According to EN 12056-1, no sewage from drainage objects may be introduced which lie 
above the backflow level and can be drained by means of gravity. 

NOTE: Make sure the national and regional applicable standards and regulations are 
observed during installation and operation.
The details in the operating instructions for the switchgear should also be observed.

DANGER! Danger of explosion!
Sewage containing faeces can lead to gas accumulation in the collection reservoir, 
which can ignite as a result of improper installation and operation. 

• If  the

 

unit is used for

 

sewage containing faeces, the valid safety regulations for poten-

tially explosive areas are to be observed.

• The switchgear is not protected against explosions and is only allowed to be operated 

outside the explosive area. 

• Breakdown barriers must be used if level sensors or float switches are used in poten-

tially explosive areas.

WARNING! Health hazard!
The materials used mean that the sewage lifting unit is not suitable for pumping pota-
ble water! 
Contact with sewage poses a health hazard. 

CAUTION! Risk of property damage!
Inappropriate materials in the system can cause damage to the product.

• Never discharge solids, fibrous substances, tar, sand, cement, ash, coarse paper, paper 

towels, cardboard, debris, rubbish, animal waste, grease, or oil. 
A grease trap should to be provided if greasy sewage accumulates.

• Improper use and overstraining causes damage to the product. The maximum possible 

inflow quantity must always be lower than the volume flow of a pump at the respective 
duty point.

Summary of Contents for DrainLift XL

Page 1: ...edieningsvoorschriften E Instrucciones de instalaci n y funcionamiento I Istruzioni di montaggio uso e manutenzione GR TR Montaj ve kullanma k lavuzu H Be p t si s zemeltet si utas t s PL Instrukcja m...

Page 2: ...Fig 10...

Page 3: ...Fig 11...

Page 4: ...etechnicianandthe responsible specialist operator before installation and commissioning It is not only the general safety instructions listed under the main point safety that must be adhered to but al...

Page 5: ...ilst the product is in operation Leakages e g from the shaft seals of hazardous fluids which are explosive toxic or hot must be led away so that no danger to persons or to the environment arises Natio...

Page 6: ...s such as heavy metals biocides pesticides acids bases salts cleaning agents and disinfectants dish washing or laundry detergents and such which have a high degree of foam formation or swimming pool w...

Page 7: ...ons Any use going over and beyond the intended use is considered to be improper 5 Product information 5 1 Type key Example DrainLift XL 2 25 3 DrainLift Sewage lifting unit XL Size 2 2 double pump sys...

Page 8: ...detailed list and description see the cata logue price list The following accessories are available Flange piece DN 80 DN 80 100 1 pc DN 80 100 already included in scope of delivery DN 100 DN 150 for...

Page 9: ...the tank is switched on and the collected sewage is automatically pumped into the connected exter nal sewage line If the water level continues to rise the second pump is activated When the high water...

Page 10: ...Make sure the installation location is ventilated sufficiently 7 1 Preparing for installation CAUTION Risk of property damage Incorrect installation can result in damage to the product Only use qualif...

Page 11: ...not be subjected to any pipeline forces or torques The pipes including valves are to be fastened and supported in such a manner that neither tensile nor compressive forces are applied to the unit All...

Page 12: ...surge like water entry and strong air entry are avoided as much as possible It is possible to connect the inlet pipe into the vertical surface above the horizontal con nection surface Leave out the a...

Page 13: ...ightness of the pipe connection depends on this decisively Fig 6 Setting up the inlet port DN 150 DN 100 1 1 Define the position of the middle of the inlet and mark it Cut the hole using the keyhole s...

Page 14: ...Secure the venting pipe against slipping out using clamps and always install with a downward incline toward the unit 7 3 4 Emergency drain connection diaphragm hand pump It is always recommended to i...

Page 15: ...5 A slow DrainLift XL 2 15 25 A slow DrainLift XL 2 20 25 A slow DrainLift XL 2 25 25 A slow NOTE To increase the operational reliability it is mandatory for an automatic circuit breaker which disconn...

Page 16: ...arrier and the switchgear and tighten the housing screws DANGER Danger of explosion If a level sensor is used in potentially explosive areas there is a danger of explosion Always use a breakdown barri...

Page 17: ...e pressure pipeline is completely filled The filling level in the tank must not rise when the discharge piping is filled and the inlet closed If the filling level continues to rise the flap of the non...

Page 18: ...owing points in particularin case of deviations from the recommended settings The filling level probe must be in contact with the base of the tank According to EN 12056 4 the switching volume should b...

Page 19: ...ime of the pumps 8 3 Decommissioning The unit must be decommissioned prior to maintenance or dismantling work WARNING Risk of burns Depending on the operating status of the system the entire pump can...

Page 20: ...subjected to maintenance by experts in accordance with EN 12056 4 The intervals must not exceed year in the case of commercial companies year for units in multi family houses 1 year for units in singl...

Page 21: ...eposits in the pump and or tank 2 Incorrect direction of rotation Swap two phases of the current feed 3 Wear to inner parts impeller bearing Replace worn parts 4 Operating voltage too low 5 Running on...

Page 22: ...ion de la directive basse tension 2006 95 CE sont respect es conform ment appendice I no 1 5 1 de la directive CE relatives aux machines 2006 42 CE Elektromagnetische Vertr glichkeit Richtlinie 2004 1...

Page 23: ...nast puj cymi dokumentami Sm rnice ES pro strojn za zen 2006 42 ES dyrektyw maszynow WE 2006 42 WE EC 2006 42 EG C le t kaj c se bezpe nosti stanoven ve sm rnici o elektrick ch za zen ch n zk ho nap...

Page 24: ...Mather and Platt Pumps Ltd Pune 411019 T 91 20 27442100 service pun matherplatt co in Indonesia WILO Pumps Indonesia Jakarta Selatan 12140 T 62 21 7247676 citrawilo cbn net id Ireland WILO Engineering...

Page 25: ...henstra e 100 44263 Dortmund T 0231 4102 7900 T 01805 W I L O K D 9 4 5 6 5 3 F 0231 4102 7126 kundendienst wilo com T glich 7 18 Uhr erreichbar 24 Stunden Technische Notfallunterst tzung Kundendienst...

Reviews: