English
10
1.2.2 Connection and electrical data
Power supply
1 ~ 230 V,
±
10%
Mains frequency
50 Hz
System of protection
IP 44
Isolation class
B
Operating mode
S1 continuous operation
Capacity max.
9
μ
F, 450V
Speed max.
max. 2900 ¹/min (50 Hz)
max. power input
see rating plate
Admission output P1
500W
Motor-output P2
400W
Conveying capacity
see rating plate
Delivery head max
see rating plate
Suction head
6m
Nominal width delivery side
40mm, 1½ “
Nominal width suction side
40mm, 1½ “
Temperature range of the flow medium:
0 up to +35°C
1.2.3
suction time
The duration of the suction process of the LP40 pump depends on the suction depth. The diagram
below shows the process duration in dependence on the depth. The mentioned time values are aver-
age values, depending from the conditions of use, they may deviate, for example by using a suction-
hose.
Ansaugzeit
0
1
2
3
4
5
6
7
0
5
10
15
Zeit t [min]
H [m]
Depth [m]
Time [min] ca.
1,0 1
2,0 2
3,0 4
4,0 6
5,0 9
6,0 10
Suction time