FUNCTIONAL CHARACTERISTICS
The heater is equipped with mounted fuel tank, low-maintenance axial fan,
high pressure spraying burner with automatic flame control, cable with
plug, socket for room thermostat and quintuple filtersystem.
Operating System:
The fan runs after starting the heater or in case of heat demand.
Fuel is drawn from the tank and pumped into the solenoid valve. The solenoid
valve opens and allows fuel to flow to the nozzle. The spark between the
electrodes will ignite the atomized fuel. The light of the flame activates the
photo-cell and ignition switches off automatically.
In case of disturbance or instable burning the flame control switches off
the heater. The operation lamp of the burner control flashes. A restart
can only be made after reset of the burner controler. In case of overheating
of the machine the safety thermostat (STB) switches off and blocks all
functions of the machine.
The manual unlocking of the safety thermostat can only be done after
elimination of the fault and cooling of the heater.
Switching to position „O“ closes the solenoid valve and the flame is
extinguished. The fan will keep running until the cooling cycle is complete.