WILMS 1221135 Operating Manual Download Page 15

- 12 of 14 -

9.

Spare Parts List

From machine no. 46-0001

Pos. Order-No.

D E S C R I P T I O N

Qty.

01

6162340

Cover

01

02

6162341

Fan Guard

01

03 

6162318

Fan Housing

01

04

6162319

Fan

01

05

6162405

Engine

01

07

3308072

Coupling Motor-Pump 

01

08

3309764

Pump

01

09

3300064

Nipple 1/4" x 7 mm

01

11

3308074

Solenoid Valve

01

12

6163416

Elbow

01

13

6162406

Condenser

01

14

6162407

Ring

02

15

6162475

Copper Connection

01

16

6162409

Elbow

01

18

6162302

Electrode 

01

19

6162476

Slide

01

21

6162303

Nozzle Holder

01

22

6162308

Baffle Plate

01

23

6162479

Nozzle

01

24

6162301

Burner Head

01

25

6162734

Flame Control

01

26

6162417

Bracket 

01

27

6162418

Thermostat

01

28

6162419

Bracket 

01

29

6162323

Combustion Chamber

01

31

6162422

Lead Through

01

32

6162423

Lead Through

02

33

6162424

Cable with Plug 

01

34

6162331

Ignition Transformer

01

35

6162426

Strip Terminal 

01

37

6162481

Strain Relief Bushing

01

38

6162428

Switch

01

39

6162808

Quick Coupling for Room Thermostat

01

41

6160160

Jumper

01

42

6162430

Contactor

01

43

6163035

Control Box

01

44

6162342

Housing Bottom

01

46

6162432

Sustainer

01

47

6162343

Side Part - Right

01

48

6162344

Side Part - Front/Back

02

49

6162345

Side Part - Left

01

50

6162436

Fuel Filter

01

51

6162490

Tank Cap

01

52

6162438

Filter

01

Summary of Contents for 1221135

Page 1: ...Perfection is our aim Oil Fired Heaters Operating Manual BV 135...

Page 2: ...current emissions EN 55011 EMC Requirements DIN EN ISO 12100 Safety of machinery EN 60335 Safety of electrical machines DIN EN ISO 13857 Safety of machinery Note The observance of DIN EN ISO 13857 re...

Page 3: ...ng without room thermostat 5 Operation Heating with room thermostat 5 Operation with warm air hose 5 2 Stopping 6 Important 6 3 Safety and control devices 6 Room thermostat 6 4 Cleaning 7 Cleaning of...

Page 4: ...tive Therefore leave the plug into the socket When ordering spare parts please give the type serial number of the heater and the part number otherwise a correct delivery is not possible The admissible...

Page 5: ...ite the atomized fuel The light of the flame activates the photo cell and ignition switches off automatically In case of disturbance or instable burning the flame control switches off the heater The o...

Page 6: ...etc It is essential that there is a sufficient ventilation of the room The heater may not be worked on or transported during operation If the heater is used for drying of grain the set up has to be i...

Page 7: ...ty kW 24 8 kcal h 21 300 Air volume m h 1 500 Pressing max total Pa 100 Max fuel consumption approx kg h 2 09 Heiz l EL or Petrolium Tank capacity Ltr 40 Dimensions L mm 1250 W mm 490 H mm 690 Weight...

Page 8: ...uring service always obbey the surface temperature from the fuel preheating device Disconnect the heater first from the power supply and let it cool down danger of burning Operation Heating without ro...

Page 9: ...utton lights up After the cause of the malfunction has been cleared the reset button can be pushed and the burner can be restarted In case the limit switch has shut off check the malfunction and elimi...

Page 10: ...by removing the drain plug on the bottom of the tank Collect the dirty fuel in an external container Rinse the fuel tank several times with clean fuel no dirt particle should remain in the tank Check...

Page 11: ...tarts shortly and Lack of fuel Check oil level in tank shutts off The red lamp lights up Air bubbles in the Check fuel suction and suction line return line Control lamp push reset button On initial st...

Page 12: ...ons or an installed exhaust pipe as shown in the drawing Never start the heaters connected to just an exhaust pipe which has been lead through the wall Use it only with an additional exhaust pipe mini...

Page 13: ...of the burner head Measure A 4 mm Measure B 2 mm Measure C 0 mm Measure D 9 mm Measure E Between 2 and 3 for approx 12 CO Burner Nozzle Danfoss 0 50 usgal h 80 S Pump Pressure 12 bar Adjustment of th...

Page 14: ...nd NK Thermostat Fan THZ Tank Heating F Photocell RT Socket for thermostat STB Safety Thermostat BA Controler lower part MV Solenoid Valve HR Relays ZT Ingnition Transformer S Switch M Motor C Condens...

Page 15: ...e 01 23 6162479 Nozzle 01 24 6162301 Burner Head 01 25 6162734 Flame Control 01 26 6162417 Bracket 01 27 6162418 Thermostat 01 28 6162419 Bracket 01 29 6162323 Combustion Chamber 01 31 6162422 Lead Th...

Page 16: ...e 01 68 1130046 Clamp Hose 02 70 6162304 Burner Cover 01 71 6161318 Safety Thermostat 01 72 6162306 Ignition Cable 02 73 6162454 Cable with Plug 01 74 6162754 Control Box Socket 01 75 6162486 Grommet...

Page 17: ...14 of 14 BV 135 Exploded view...

Reviews: