![WILMS 1221135 Operating Manual Download Page 12](http://html1.mh-extra.com/html/wilms/1221135/1221135_operating-manual_982755012.webp)
- 9 of 14 -
6.
Important Notice
These units are oil fired space heaters, equipped with a chimney connection. If
connected to a chimney the installation should be made only according to the below
drawing.
The connection should be made only with a fixed chimney according to the regulations
or an installed exhaust pipe as shown in the drawing.
Never start the heaters connected to just an exhaust pipe which has been lead through
the wall.
Use it only with an additional exhaust pipe, minimum above the ridge. In case of
horizontal outlet through the wall, use only with T-shaped pipe, refer below drawing.
Top of exhaust pipe or chimney
should be 0,5 m above ridge.
The horizontally laid exhaust pipe up to the actual chimney must be installed with a
slope of at least 10%.