Infrared Sensor Installation Instructions
DETECTION
AND
ACTIVATION
When
the
sensor
detects
a
user,
a
slow
flashing
red
light
appears
in
the
sensor
window.
After
1
to
2
seconds
of
detection,
the
light
flashes
rapidly
and
the
sensor
immediately
activates
the
solenoid
valve
to
begin
water
flow.
The
solenoid
valve
remains
open
as
long
as
the
user
is
detected.
The
solenoid
valve
turns
off
when
the
user
is
no
longer
detected.
The
sensor
is
set
to
activate
the
solenoid
for
a
maximum
of
30
seconds
before
automatically
shutting
off.
INSTALLATION
AND
REPLACEMENT
1.
Disconnect
24Vac
power
at
the
transformer
or
fuse
box.
2.
Remove
top
cover
to
expose
sensors.
3.
Install
new
sensor.
Make
sure
sensor
arrow
is
pointing
up.
See
figure
1
.
4.
Connect
the
red
male
power
cable
to
the
red
female
connector
on
the
sensor.
See
figure
2
.
5.
Connect
the
black
female
solenoid
cable
to
the
black
male
connector
on
the
sensor.
See
figure
2
.
6.
Replace
top
cover
removed
in
step
2.
7.
Reconnect
power.
Figure
1
Solenoid
Valve
24Vac
Plugin
Transformer
IR
sensor
P/N
‐
701210
Red
Blk
Pwr
Out
P/N
‐
700150
Figure
2
Willoughby Industries
Infrared
Lavatory
Sensor
Installation
Instructions
Back
of
Sensor