Gas-Fired Steam Boilers – 

User’s Information Manual

To locate Lighting Instructions:

Find your boiler model number on boiler nameplate (begins with GSA). Read the valve manufacturer’s model and
name on the boiler gas valve. Locate the correct “Lighting Instruction” using the table below. Use only the Instructions
applying to your boiler model and gas valve. If you are in doubt which to use, please contact your boiler installer/
technician for assistance.

Maintain your boiler using this schedule:

GSA

 

standing pilot

With gas valve:

Boiler models

Page

Honeywell VR8200 or VR8300

GSA-075 through GSA-250

4

Robertshaw 7200

GSA-075 through GSA-175

5

Service technician

(covered in Boiler Manual — for use only by a 

qualified service technician

)

Owner maintenance

(see pages 6 – 8 for instructions)

A

NN

NUA

L

 

ST

A

R

T

-

UP

  

Inspect:

•  Reported problems

•  Boiler area

•  Air openings

•  Flue gas vent system

•  Pilot and main burner flames

•  Piping

•  Boiler heating surfaces

•  Burners and base 

  

Service:

•  Gauge glass

  

Start-up:

•  Perform start-up per manual

  

Check/test:

•  Gas piping

•  Boiler waterline

•  Limit controls and cutoffs

•  Boiler relief valve

  

Review:

•  Review with owner

   Daily

•  Check boiler area

•  Check boiler pressure gauge

•  Check air openings

   Monthly

•  Check boiler and system piping

•  Check venting system

•  Check/operate boiler relief 

valve

•  Check pilot and main burner 

flames

   Periodically

•  Test low water cutoff

   End of season

•  Shut down procedure

Summary of Contents for RVGP

Page 1: ...e gas odorant Propane boilers only Your propane supplier mixes an odorant with the propane to make its pres ence detectable In some instances the odorant can fade and the gas may no longer have an odo...

Page 2: ...5 Should overheating occur or gas supply fail to shut off do not turn off or disconnect electrical supply to pump Instead shut off the gas supply at a location external to the appliance 6 DO NOT use t...

Page 3: ...75 through GSA 250 4 Robertshaw 7200 GSA 075 through GSA 175 5 Service technician covered in Boiler Manual for use only by a qualified service technician Owner maintenance see pages 6 8 for instructio...

Page 4: ...to the appliance 5 When equipped with Johnson Controls vent damper Model M35 manually rotate damper blade in direction of arrow to Open position indicated on damper assembly 6 Turn gas control knob cl...

Page 5: ...n to inspect the appliance and to replace any part of the control system and any gas control which has been under water 1 Stop Read the safety information above on this label 2 Set the thermostat to l...

Page 6: ...ing section failure Do not use petroleum based cleaning or sealing compounds in boiler system Severe damage to boiler and system components can occur resulting in possible severe personal injury death...

Page 7: ...g the heating season to verify the valve and discharge piping flow freely If corrosion and or deposits are noticed within the valve body testing must be performed more often A try lever test must also...

Page 8: ...ant use of makeup water Call qualified service technician to de lime boiler if necessary In some cases deposits will be too heavy to remove with de liming procedures Have qualified service technician...

Reviews: