background image

5

Part Number 550-110-739/0703

GSA

 

Gas-Fired Steam Boilers – 

User’s Information Manual

Gas valve 

— 

Robertshaw 7200

FOR YOUR SAFETY READ BEFORE LIGHTING

Lighting Instructions

GSA-075 through GSA-175

If you do not follow these instructions exactly, a fire or explosion may result caus-
ing property damage, personal injury or loss of life.

1. Set the thermostat to lowest setting.

2. Turn off all electric power to the appliance if service is to be

performed.

3. Remove front panel.

4. Depress and move selector arm left 

 to 

OFF

.

5. Replace front panel.

LIGHTING INSTRUCTIONS

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in
your building.

Immediately call your gas supplier from a neighbor’s phone.
Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

A. This appliance has a pilot, which must be

lighted by hand. When lighting the pilot, follow
these instructions exactly.

B. Before 

LIGHTING

, smell all around the

appliance area for gas. Be sure to smell next
to the floor because some gas is heavier than
air and will settle on the floor. See below.

C. Use only your hand to push down the reset button or turn the gas control

knob. Never use tools. If the knob or reset button will not operate by hand,
don't try to repair it, call a qualified service technician. Force or attempted
repair may result in a fire or explosion.

D. Do not use this appliance if any part has been under water. Immediately call

a qualified service technician to inspect the appliance and to replace any
part of the control system and any gas control, which has been under water.

1.

Stop!

  Read the safety information above on this label.

2. Set the thermostat to lowest setting.

3. When equipped with 

Effikal 

vent damper 

Model RVGP,

 place

service switch in 

Hold Damper Open

 position.

4. Turn off all electrical power to the appliance.

5. When equipped with 

Johnson Controls 

vent damper 

Model

M35,

 manually rotate damper blade in direction of arrow to

Open 

position indicated on damper assembly.

6. Depress and move selector arm left 

 to 

OFF.

7. When equipped with vent damper, verify damper blade is in

full open position.

8. Wait five (5) minutes to clear out any gas. Then smell for

gas, including near the floor. If you smell gas, 

STOP!

 Follow

"B"

 in the safety information above. If you don't smell gas,

go to the next step.

9. Remove access panel located above burners.

10. Find pilot — follow metal tube from gas control.

The pilot is between two burners behind the
access panel.

11. Move selector arm on gas control right 

to 

SET 

position.

12. Hold selector arm in 

SET 

position and immediately light the

pilot with a match. Continue to hold selector arm to 

SET 

for

about one-half (

1

/

2

) minute after the pilot is lit.

13. Release selector arm. If pilot does not remain lit, repeat steps

6 through 13.

If the pilot will not stay lit after several tries, move selector
arm left 

 to 

OFF 

and call your service technician or gas

supplier.

14. Replace access panel.

15. Turn selector arm left 

 to 

ON

.

16. Turn on all electric power to the appliance.

17. When equipped with 

Effikal 

vent damper, place service

switch in 

Automatic Operation

 position.

18. Set thermostat to desired setting.

19. Replace front panel.

TO TURN  OFF  GAS TO THE  APPLIANCE

Summary of Contents for RVGP

Page 1: ...e gas odorant Propane boilers only Your propane supplier mixes an odorant with the propane to make its pres ence detectable In some instances the odorant can fade and the gas may no longer have an odo...

Page 2: ...5 Should overheating occur or gas supply fail to shut off do not turn off or disconnect electrical supply to pump Instead shut off the gas supply at a location external to the appliance 6 DO NOT use t...

Page 3: ...75 through GSA 250 4 Robertshaw 7200 GSA 075 through GSA 175 5 Service technician covered in Boiler Manual for use only by a qualified service technician Owner maintenance see pages 6 8 for instructio...

Page 4: ...to the appliance 5 When equipped with Johnson Controls vent damper Model M35 manually rotate damper blade in direction of arrow to Open position indicated on damper assembly 6 Turn gas control knob cl...

Page 5: ...n to inspect the appliance and to replace any part of the control system and any gas control which has been under water 1 Stop Read the safety information above on this label 2 Set the thermostat to l...

Page 6: ...ing section failure Do not use petroleum based cleaning or sealing compounds in boiler system Severe damage to boiler and system components can occur resulting in possible severe personal injury death...

Page 7: ...g the heating season to verify the valve and discharge piping flow freely If corrosion and or deposits are noticed within the valve body testing must be performed more often A try lever test must also...

Page 8: ...ant use of makeup water Call qualified service technician to de lime boiler if necessary In some cases deposits will be too heavy to remove with de liming procedures Have qualified service technician...