background image

16

Design Excellence : Cool Technology

www.williams-refrigeration.com

0699_

Medi+ O&M (E) | Rev 1 | November 2020

Williams Refrigeration Australia

38-42 Gaine Road
Dandenong South, Victoria 3175
Australia
Tel: +61 3 8787 4747 
Fax: +61 3 8787 4787

[email protected]
www.williams-refrigeration.com.au

Williams Refrigeration

Bryggen Road
North Lynn Industrial Estate
King’s Lynn
Norfolk PE30 2HZ
Sales Tel: +44 1553 817000 
Sales Fax: +44 1553 817111
Spares Tel: +44 1553 817017 
Spares Fax: +44 1553 817020

[email protected]
www.williams-refrigeration.co.uk

Williams Refrigeration Hong Kong

Unit C, 12/F., Roxy Industrial 
Centre,
58 - 66 Tai Lin Pai Road, Kwai 
Chung,  
New Territories, Hong Kong
Tel: +852 2407 5422 
Fax: +852 2407 3767

[email protected]
www.williams-refrigeration.com.hk

Williams Silver Frost

2 rue Conventionnel Huguet
23000 GUERET
France
Tel: +33 5 55 52 27 88 
Fax: +33 5 55 62 10 61

[email protected]
www.williams-refrigeration.fr

Williams Dubai

603-604 Building 1B
Dubai Design District
P.O. Box 333215
Dubai
United Arab Emirates
Tel: +971 4 510 8203 

[email protected]

Williams Refrigeration is a trading name of AFE Group Limited.
Registered in England & Wales under Registered Number 
3872673.   Registered Office Address - Bryggen Road,  
North Lynn Industrial Estate, King’s Lynn, Norfolk, PE30 2HZ

Summary of Contents for Medi+ LWMP620

Page 1: ...nd will use the necessary safety equipment and take the necessary precautions required of their intended work Improper installation maintenance or repair may put the user at considerable risk Williams...

Page 2: ...led by persons who are appropriately trained skilled and competent to properly and safely carry out the work and serviced by qualified engineers for the handling of hydrocarbon refrigerants Ensure pro...

Page 3: ...the replacement of parts is required the equipment must be safely disconnected and isolated from the power supply using a lock off system at the isolation device It is advised that the electrical sup...

Page 4: ...iosafety Manual source World Health Organisation Laboratory Biosafety Manual the current edition IMPORTANT SAFETYINFORMATION INFORMATION ON PRODUCT LIABILITY In the following cases the designated prot...

Page 5: ...ay to reveal the polished stainless steel surface Care should be taken to ensure that no adhesive residue remains on the surface Any stubborn or tough adhesive marks can be removed by following the ad...

Page 6: ...party supervisory networks and systems such as Building Management Systems BMS and IoT cloud based systems via an RS485 Modbus data connection This will allow for a comprehensive supervision of the eq...

Page 7: ...e even loading Do not place items against the rear plenum or pushed against side walls When loading the appliance please ensure that its load is equally distributed throughout and ensure air can circu...

Page 8: ...essing the i button While keeping the i button pressed press the x button to reset the value To exit the information menu either wait 10 seconds or press the x button Alarms An alarm is reported via t...

Page 9: ...tinue in normal sequence Instead the compressor will switch to a five minute cycle which it cycles on for five minutes then off for five minutes The normal compressor cycle will be restored upon the r...

Page 10: ...ugher spots creamy polishes like CIF original cream can be effective Light pressure should be used when cleaning with the grain The cleaning process should be repeated in order to prevent any dirt bec...

Page 11: ...hould be checked and cleaned regularly and replaced if damaged To clean the gasket wipe with warm soapy water and a soft cloth ensuring it is completely dry before closing the door DO NOT use a sharp...

Page 12: ...ing Shut door Remove cover and clean condenser fins with a clean brush TROUBLE SHOOTING INFORMATION FOR THE MAINS POWER SUPPLY FAILURE ALARM OPTIONAL Fault Possible Cause Action The sounder is not wor...

Page 13: ...same quality and standard as we use to build your appliance and have been rigorously checked tested and inspected to ensure the very best quality and exact fit You can contact us directly for everythi...

Page 14: ...number and date of installation The serial number is located on the product identification plate inside the cabinet modular product door frame or similar location It is recommended that operators shou...

Page 15: ...ent that may affect performance 14 The customer permits persons other than those authorised by Williams Refrigeration to perform or affect repairs or adjustments to the equipment 15 If authorised repr...

Page 16: ...k Williams Refrigeration Hong Kong Unit C 12 F Roxy Industrial Centre 58 66 Tai Lin Pai Road Kwai Chung New Territories Hong Kong Tel 852 2407 5422 Fax 852 2407 3767 sales williams hongkong com www wi...

Reviews: