APPLIANCE ROUTINE MAINTENANCE / CLEANING

APPLIANCE ROUTINE MAINTENANCE / CLEANING

ROUTINE MAINTENANCE

Safely disconnect the appliance from the 

power supply before cleaning, servicing or 

undertaking general maintenance.

We recommend that you undertake regular 

preventative maintenance using a qualified 

 

service provider in order to get the best from  

your equipment.

CLEANING

 

Always wear appropriate personal protective 

equipment (PPE) when cleaning the appliance. Care 

should be taken for parts with possible sharp edges. 
Stainless steel is naturally corrosion-proof and 

needs no additional protective coating to maintain 

its gloss and usability for a long time. 
Abrasive or corrosive cleaning agents should never 

be used. These can damage surfaces and cause 

corrosion. They include: 
• 

Cleaners containing chloride; 

• 

Bleaches containing hypochlorite (if accidentally 

spilled on stainless steel, rinse off with water 

immediately and thoroughly); 

• 

Silver polish 

If the cabinet exterior is looked after correctly it will 

retain an “as new” finish for many years. A damp 

cloth is usually sufficient for wiping away light dirt 

and finger marks and normal day to day cleaning 

should be carried out with a soft cloth and soapy 

water. 
Dry thoroughly afterwards and where possible 

remove all racking and shelving fittings to aid the 

process. 
For stainless steel with visible polishing grains, clean 

the steel with the grain - not against the grain. When 

water has been used for cleaning or rinsing, wipe 

the surface dry to prevent water from drying and 

forming watermarks, especially in areas with hard 

water. Avoid this type of watermark by using distilled 

water. 
For tougher spots, creamy polishes like CIF original 

cream can be effective. Light pressure should be 

used when cleaning with the grain. The cleaning 

process should be repeated in order to prevent any 

dirt becoming lodged in the surface grain again. 

CIF original cream cleaner can also be used 

for wiping off water spots and can alleviate 

discoloration. Remove this type of residue by rinsing 

with clean, preferably distilled water and wipe away 

any remaining streaks of polish or watermarks. 
Tough grease or oil marks can also be removed 

using denatured alcohol or acetone. There is no risk 

of corroding stainless steel by using such solvents. 

For ease of use limit the amount of solvent used. 

Wash more than once using a pure solvent on a 

clean soft rag until all traces of the greasy residue 

are removed. 

Specialist Stainless Steel Cleaners 

 

Innosoft B570 is a special deep cleaner that is 

suitable for the intensive cleaning of contaminated 

stainless steel surfaces, and removes stains and 

oxides in a single operation. 
Innoclean B580 completely removes any residues 

left after the use of Innosoft B570 and passivates 

the surface which helps to prevent further 

corrosion.
With regards to the above recommended cleaners, 

always check that they will not have any detrimental 

effect to the stored contents.

SHELF / SUPPORT/ RACKING REMOVAL 

First remove the shelves, then remove the shelf 

supports by grasping firmly in the centre and lifting 

slightly. Turn the shelf support towards the interior 

of the cabinet by pushing it in the centre as you 

twist the support through 90°. The shelf support 

will be released. (NB: the supports are designed 

to be anti-tilt and you may therefore experience 

some resistance at first which will be overcome with 

practice). When all shelves have been removed, 

remove the racking by lifting up and over the nylon 

retaining blocks.

Summary of Contents for Medi+ LWMP620

Page 1: ...nd will use the necessary safety equipment and take the necessary precautions required of their intended work Improper installation maintenance or repair may put the user at considerable risk Williams...

Page 2: ...led by persons who are appropriately trained skilled and competent to properly and safely carry out the work and serviced by qualified engineers for the handling of hydrocarbon refrigerants Ensure pro...

Page 3: ...the replacement of parts is required the equipment must be safely disconnected and isolated from the power supply using a lock off system at the isolation device It is advised that the electrical sup...

Page 4: ...iosafety Manual source World Health Organisation Laboratory Biosafety Manual the current edition IMPORTANT SAFETYINFORMATION INFORMATION ON PRODUCT LIABILITY In the following cases the designated prot...

Page 5: ...ay to reveal the polished stainless steel surface Care should be taken to ensure that no adhesive residue remains on the surface Any stubborn or tough adhesive marks can be removed by following the ad...

Page 6: ...party supervisory networks and systems such as Building Management Systems BMS and IoT cloud based systems via an RS485 Modbus data connection This will allow for a comprehensive supervision of the eq...

Page 7: ...e even loading Do not place items against the rear plenum or pushed against side walls When loading the appliance please ensure that its load is equally distributed throughout and ensure air can circu...

Page 8: ...essing the i button While keeping the i button pressed press the x button to reset the value To exit the information menu either wait 10 seconds or press the x button Alarms An alarm is reported via t...

Page 9: ...tinue in normal sequence Instead the compressor will switch to a five minute cycle which it cycles on for five minutes then off for five minutes The normal compressor cycle will be restored upon the r...

Page 10: ...ugher spots creamy polishes like CIF original cream can be effective Light pressure should be used when cleaning with the grain The cleaning process should be repeated in order to prevent any dirt bec...

Page 11: ...hould be checked and cleaned regularly and replaced if damaged To clean the gasket wipe with warm soapy water and a soft cloth ensuring it is completely dry before closing the door DO NOT use a sharp...

Page 12: ...ing Shut door Remove cover and clean condenser fins with a clean brush TROUBLE SHOOTING INFORMATION FOR THE MAINS POWER SUPPLY FAILURE ALARM OPTIONAL Fault Possible Cause Action The sounder is not wor...

Page 13: ...same quality and standard as we use to build your appliance and have been rigorously checked tested and inspected to ensure the very best quality and exact fit You can contact us directly for everythi...

Page 14: ...number and date of installation The serial number is located on the product identification plate inside the cabinet modular product door frame or similar location It is recommended that operators shou...

Page 15: ...ent that may affect performance 14 The customer permits persons other than those authorised by Williams Refrigeration to perform or affect repairs or adjustments to the equipment 15 If authorised repr...

Page 16: ...k Williams Refrigeration Hong Kong Unit C 12 F Roxy Industrial Centre 58 66 Tai Lin Pai Road Kwai Chung New Territories Hong Kong Tel 852 2407 5422 Fax 852 2407 3767 sales williams hongkong com www wi...

Reviews: