7.  Equipment manufactured to the customers’ own 

design, Williams Refrigeration will not be liable 

for any defect, non performance or improper 

operation of the equipment arising from any 

drawing design or specification supplied by the 

customer, their representative or agent.

8.  Second hand equipment.
9.  The customer uses or installs the equipment in 

such a way that it exceeds its design envelope or 

operates the equipment at control parameters 

other than those provided as standard factory 

settings.

10. The customer fails to observe commonly 

accepted operating practices.

11. The customer has not properly cleaned or 

maintained the equipment or carried out 

necessary servicing, including cleaning of the 

condenser, in accordance with instructions, 

literature or directions issued by Williams 

Refrigeration. (Operating Instructions are 

supplied with all equipment but also available at 

www.williams-refrigeration.co.uk).

12. Equipment fails through improper installation by 

others, misuse, abuse, accidental damage, power 

loss or fluctuations, fire, flooding or acts of god.

13. Any third party item(s) connected to the 

equipment that may affect performance.

14. The customer permits persons other than 

those authorised by Williams Refrigeration to 

perform or affect repairs or adjustments to the 

equipment.

15. If authorised representatives of Williams 

Refrigeration are denied full and free rights of 

access to the equipment for inspection during 

normal business hours as previously stated.

16. If Repairs are made using spare parts 

or replacement items not supplied or 

preauthorised by Williams Refrigeration.

17. The initial equipment supply date shall apply for 

warranty validity for the subsequent supply of 

replacement of parts or products.

EXTENDED WARRANTY 

Extended Warranty offers the opportunity to protect 

your equipment (subject to conditions outlined) for 

an additional period of up to 5 years inclusive of 

original warranty periods.
Should you require Extended Warranty, state on 

your order or notify the Dealer or Williams Sales 

Manager at the time of purchase and they will be 

able to arrange it for you.
To ensure your Extended Warranty Policy remains 

valid, at least one maintenance / service visit per 

year must take place in years 2, 3, 4 and 5.

For further information or clarification please 

call 01553 817000 or email to 

 

[email protected] or write to 

Williams Refrigeration, Bryggen Road, King’s 

Lynn, Norfolk, PE30 2HZ

Summary of Contents for Medi+ LWMP620

Page 1: ...nd will use the necessary safety equipment and take the necessary precautions required of their intended work Improper installation maintenance or repair may put the user at considerable risk Williams...

Page 2: ...led by persons who are appropriately trained skilled and competent to properly and safely carry out the work and serviced by qualified engineers for the handling of hydrocarbon refrigerants Ensure pro...

Page 3: ...the replacement of parts is required the equipment must be safely disconnected and isolated from the power supply using a lock off system at the isolation device It is advised that the electrical sup...

Page 4: ...iosafety Manual source World Health Organisation Laboratory Biosafety Manual the current edition IMPORTANT SAFETYINFORMATION INFORMATION ON PRODUCT LIABILITY In the following cases the designated prot...

Page 5: ...ay to reveal the polished stainless steel surface Care should be taken to ensure that no adhesive residue remains on the surface Any stubborn or tough adhesive marks can be removed by following the ad...

Page 6: ...party supervisory networks and systems such as Building Management Systems BMS and IoT cloud based systems via an RS485 Modbus data connection This will allow for a comprehensive supervision of the eq...

Page 7: ...e even loading Do not place items against the rear plenum or pushed against side walls When loading the appliance please ensure that its load is equally distributed throughout and ensure air can circu...

Page 8: ...essing the i button While keeping the i button pressed press the x button to reset the value To exit the information menu either wait 10 seconds or press the x button Alarms An alarm is reported via t...

Page 9: ...tinue in normal sequence Instead the compressor will switch to a five minute cycle which it cycles on for five minutes then off for five minutes The normal compressor cycle will be restored upon the r...

Page 10: ...ugher spots creamy polishes like CIF original cream can be effective Light pressure should be used when cleaning with the grain The cleaning process should be repeated in order to prevent any dirt bec...

Page 11: ...hould be checked and cleaned regularly and replaced if damaged To clean the gasket wipe with warm soapy water and a soft cloth ensuring it is completely dry before closing the door DO NOT use a sharp...

Page 12: ...ing Shut door Remove cover and clean condenser fins with a clean brush TROUBLE SHOOTING INFORMATION FOR THE MAINS POWER SUPPLY FAILURE ALARM OPTIONAL Fault Possible Cause Action The sounder is not wor...

Page 13: ...same quality and standard as we use to build your appliance and have been rigorously checked tested and inspected to ensure the very best quality and exact fit You can contact us directly for everythi...

Page 14: ...number and date of installation The serial number is located on the product identification plate inside the cabinet modular product door frame or similar location It is recommended that operators shou...

Page 15: ...ent that may affect performance 14 The customer permits persons other than those authorised by Williams Refrigeration to perform or affect repairs or adjustments to the equipment 15 If authorised repr...

Page 16: ...k Williams Refrigeration Hong Kong Unit C 12 F Roxy Industrial Centre 58 66 Tai Lin Pai Road Kwai Chung New Territories Hong Kong Tel 852 2407 5422 Fax 852 2407 3767 sales williams hongkong com www wi...

Reviews: