FORSAIRE COUNTERFLOW DIRECT VENT GAS WALL HEATER
23
Lighting Instructions
-
ELECTRONIC
(INTERMITTENT)
IGNITION
1.
STOP!
Read the safety information above.
2.
Set the thermostat to its lowest setting.
3.
Turn off all electric power to the appliance.
4. This appliance is equipped with an ignition device
which automatically lights the pilot. Do not try to light
the pilot by hand.
5.
Remove the control access panel.
6. Turn the gas control knob clockwise to “OFF”.
7.
Wait five (5) minutes to clear out any gas, then smell
for gas, including near the floor. If you smell gas, stop!
Follow “B” In the safety information above. If you don’t
smell gas, go to the next step.
8. Turn the gas control knob counterclockwise
to “ON”.
9. Replace the control access panel.
10. Turn on all electric power to the appliance.
11. Turn the thermostat to the “ON” (HEAT) position. Set
the thermostat higher than room temperature. The
pilot will automatically light and the main burner(s)
will light in approximately 45 seconds.
NOTE:
On initial start-up or after prolonged shut down,
several ignition cycles may be required to purge the gas
lines. To accomplish the recycle - repeat steps 6 through 11
until the pilot is established.
12. Set the thermostat to the desired setting.
13. After the room thermostat turns the system off, a
delay of approximately one minute is required before
the system can be turned on again.
14. If the appliance will not operate, follow the
instructions “To Turn Off Gas To Appliance” and call
your service technician or gas supplier.
TO TURN OFF GAS TO APPLIANCE
1. Set the thermostat to its lowest setting.
2.
Turn off all electric power to the appliance if service
is to be performed.
3.
Remove the control access panel.
4. Push in the gas control knob slightly and turn it
clockwise to “OFF”. Do not force the gas
control knob.
5.
Replace the control access panel.
IMPORTANT:
KEEP BURNER AND CONTROL
COMPARTMENT CLEAN.
WARNING:
DUE TO HIGH SURFACE
TEMPERATURES - KEEP CHILDREN, CLOTHING,
FURNITURE OR ANY COMBUSTIBLE MATERIAL AWAY
FROM THE FURNACE. Make sure the “FOR YOUR
SAFETY” hang tag (see below) hangs below the heat shield.