Disassembly and Assembly: Ink and Top Up Reservoir Sensor
Issue 2
117
Part No. 306-0430-102
Ink and Top Up Reservoir Sensor
Removal
1
Cut the four wires (sensor and LED connections).
2
Unscrew the sensor from the threaded receptacle on top of the reservoir and list it out.
Installation
1
Screw the level detector into the receptacle in the tank.
2
Thread heatshrink over the four lead ends.
3
Solder the leads to the wires cut in
Removal
step
1
.
Exchanging the Sensor and LED
1
3
2
4
6
5
7
(
1
) Level Detect Retainer
(
5
) Spacer
Tube
(
2
) O-ring
(
6
) Lens
Retainer
(
3
) Lens
(
7
) Sensor and LED
(
4
) Sensor
Holder
Figure 55 Level Detector
1
Remove the sensor from the tank as described above.
2
Unscrew the lens retainer (Figure 55 (
6
)) and thread it over the trailing leads of the sensor and LED.
3
Withdraw the spacer tube (
5
), sensor holder (
4
), lens (
3
) and O-ring (
2
) from the level detect retainer (
1
).
4
Remove the sensor and LED from the sensor holder (
4
) and discard the sensor and LED.
Summary of Contents for 430
Page 1: ...430 Ink Jet Printer Service Manual THE WORLD S CODING AND LABELLING COMPANY ...
Page 7: ...430 Ink Jet Printer Service and Maintenance Manual vi Issue 2 Part No 306 0430 102 ...
Page 17: ...430 Ink Jet Printer Service and Maintenance Manual xvi Issue 2 Part No 306 0430 102 ...
Page 31: ...430 Ink Jet Printer Service and Maintenance Manual 14 Issue 2 Part No 306 0430 102 ...
Page 61: ...430 Ink Jet Printer Service and Maintenance Manual 44 Issue 2 Part No 306 0430 102 ...
Page 161: ...430 Ink Jet Printer Service and Maintenance Manual 144 Issue 2 Part No 306 0430 102 ...
Page 181: ...430 Ink Jet Printer Service and Maintenance Manual 164 Issue 2 Part No 306 0430 102 ...
Page 200: ... ...
Page 202: ... ...