N
IGHT
S
CAN
U
NIVERSAL
R
EMOTE
C
ONTROL
S
YSTEM
O
PERATOR
’
S
M
ANUAL
TP-5543301-C
5-7
July 2018
Table 5-5 Wireless J-Box and Wireless HHRC Codes
Message
Meaning
Root Issue
Potential Cause
8,07
Unrecoverable
communication error
No successful poll / response
communication for 250ms.
J-
Box is not ‘talking’ to any
other board. Check Base
Board flashes and HHRC
display for x,07.
8,08
Internal firmware
detected error
Internal state machine logic has
detected an invalid state transition.
Firmware logic error.
8,09
RF module error
XBee plug-in module did not properly
initialize.
Bad module.
8,10
Memory Error
Memory Error
8,11
HHRC power up
negotiation failed
Unit could not establish
communication with any HHRC
(wired or wireless) when the NS 3.0 /
4.5 was powered up.
Panel Mount = unit 3, Wireless HHRC
= unit 6, J-Box = unit 8.
System can have a panel mount
remote and an HHRC, or 2 HHRCs,
but never 3 remote units.
Negotiation happens every time the
Base unit is powered up w/push-pull
switch
.
Wireless HHRC is not
p
lugged in during “Pull to
Start” power-up.
8,12
In-system
reprogramming failed
Dip-switch activated in-system
reprogramming of attached devices
was not able to successfully
complete.
Summary of Contents for NIGHT SCAN