10 Appendix
10.1 Model with Auxiliary Air Supply (No Compressor)
The Night Scan Chief comes standard with an air compressor to deliver air to the mast, however
an optional air valve in conjunction with customer supplied air source may be used instead. This
section discusses the differences a Night Scan Chief with air valve will have from a standard
model. Be sure to read and understand the Safety Summary Section 1 before beginning any
installation procedure.
10.1.1
Supply Air Requirements
Table 10-1 describes specifications for supply air that apply to the Night Scan Chief with Air
Valve.
10.1.2
Installing Supply Air Connections
A barbed fitting is provided for connecting the air-line required to pressurize the system. Air may
be supplied externally by a compressor or other source of clean, dry air with a maximum pres
-
sure of 90 psi (6.2 bar). The unit has an internal regulator factory set to 20 psi (1.4 bar). Figure
10-1 shows the location of the air inlet. The inlet fitting is to be used with a 3/8 inch (or equivalent
metric) inside diameter air hose rated for the pressure supplied in combination with environmen
-
tal factors, which may derate the hose (e.g. high temperatures). The unit is supplied with 20 feet
(6 m) of air hose labeled SUPPLY to designate the pressurized air to be routed to the INLET of
the unit. As with standard models, mast air exhausts within the base cover during retraction.
Table 10-1 Night Scan Chief with Air Valve Specifications
Parameter
Value
Mast Air Volume (NSC 1.8)
1.4 cubic feet (0.04 cubic meters)
Mast Air Volume (NSC 2.3)
1.7 cubic feet (0.05 cubic meters)
Maximum Mast Operating Air Pressure
20 psi (1.4 bar) in the mast
Maximum Supply Air Pressure
90 psi (6.2 bar) applied to regulator inlet
Summary of Contents for Night Scan Chief 1.0
Page 2: ......
Page 6: ...PAGE 4 OF 80 NIGHT SCAN CHIEF OPERATING INSTRUCTIONS TP 4602001 T DECEMBER 2020 ...
Page 22: ...PAGE 20 OF 80 NIGHT SCAN CHIEF OPERATING INSTRUCTIONS TP 4602001 T DECEMBER 2020 ...
Page 55: ...PAGE 53 OF 80 NIGHT SCAN CHIEF OPERATING INSTRUCTIONS TP 4602001 T DECEMBER 2020 ...
Page 56: ...PAGE 54 OF 80 NIGHT SCAN CHIEF OPERATING INSTRUCTIONS TP 4602001 T DECEMBER 2020 ...
Page 57: ...PAGE 55 OF 80 NIGHT SCAN CHIEF OPERATING INSTRUCTIONS TP 4602001 T DECEMBER 2020 ...
Page 58: ...PAGE 56 OF 80 NIGHT SCAN CHIEF OPERATING INSTRUCTIONS TP 4602001 T DECEMBER 2020 ...
Page 59: ...PAGE 57 OF 80 NIGHT SCAN CHIEF OPERATING INSTRUCTIONS TP 4602001 T DECEMBER 2020 ...
Page 60: ...PAGE 58 OF 80 NIGHT SCAN CHIEF OPERATING INSTRUCTIONS TP 4602001 T DECEMBER 2020 ...
Page 62: ...PAGE 60 OF 80 NIGHT SCAN CHIEF OPERATING INSTRUCTIONS TP 4602001 T DECEMBER 2020 ...
Page 63: ...PAGE 61 OF 80 NIGHT SCAN CHIEF OPERATING INSTRUCTIONS TP 4602001 T DECEMBER 2020 ...
Page 64: ...PAGE 62 OF 80 NIGHT SCAN CHIEF OPERATING INSTRUCTIONS TP 4602001 T DECEMBER 2020 ...
Page 76: ...PAGE 74 OF 80 NIGHT SCAN CHIEF OPERATING INSTRUCTIONS TP 4602001 T DECEMBER 2020 ...
Page 81: ...PAGE 79 OF 80 NIGHT SCAN CHIEF OPERATING INSTRUCTIONS TP 4602001 T DECEMBER 2020 ...
Page 82: ...PAGE 80 OF 80 NIGHT SCAN CHIEF OPERATING INSTRUCTIONS TP 4602001 T DECEMBER 2020 ...