background image

24

English

English

INSTALLATION AND DISASSEMBLY OF HEAT DISCHARGE PIPE

Install heat discharge pipe

1.  Rotate joint A and joint B clockwise into the two ends of heat discharge pipe.

clockwise

joint B+C

clockwise

joint A

clasp

groove

the side with ”TOP” is upwards

heat discharge pipe

2.  Insert joint A of heat discharge pipe (the side with ”TOP” is upwards) into the 

groove until you hear a ”klikk”sound.

3.  Aim the locating pole of joint B of heat discharge pipe at the opening of joint C; 

rotate it slightly to make joint B and joint C connect tightly.

joint B+C

tightened status

opening

locating pole

Summary of Contents for Cool 12

Page 1: ...Cool 7 Cool 12 Wilfa Air Conditioner Bruksanvisning Bruksanvisning Betjeningsvejledning Käyttöohje Operating Instructions ...

Page 2: ...duction for Buttons on Remote Controller 9 Function Introduction for Combination Buttons 11 Operation Guide 11 Replacement of Batteries in Remote Controller 11 Clean and Maintenance 12 Malfunction Analysis 14 Installation Precaution 17 Preparation before Installation 19 Install Wire Hook 20 Removing Collected Water 21 Installation and Disassembly of Heat Discharge Pipe 24 Electric Schematic Diagra...

Page 3: ...nce Cleaning and user maintenance shall not be made by children without supervision If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualifi ed persons in order to avoid a hazard Explanation of Symbols DANGER Indicates a hazardous situation that if not avoided will result in death or serious injury WARNING Indicates a hazardous situation that if ...

Page 4: ...o not operate the air conditioner at humid environment Please keep air inlet and air outlet clean no obstacles During operation close doors and windows to improve cooling effect Please put the air conditioner at smooth and flat ground for operation to avoid noise and vibration This air conditioner is equipped with castors Castors should slide at smooth and flat ground Prohibit inclining or turning...

Page 5: ...oller panel Guide louver Swing louver Castor Wire fixing hook Plug of power cord Filter Air inlet Joint A Heat discharge pipe Joint B C NOTICE Heat discharge pipe and other installation accessories can t be discarded Remote controller ...

Page 6: ...est position in the COOL or DRY mode with the fan speed set to Low for an extended period of time Condensation may form on the louvers 2 Left right air flow direction Hold the vertical louver as shown in the diagram and adjust the air flow direction CAUTION Do not adjust the vertical louvers to the extreme left or right in the COOL or DRY mode with the fan speed set to Low for an extended period o...

Page 7: ...nixie tube on control panel won t display Under ON status dual 8 nixie tube on control panel will display set temperature Under another mode it won t display 1 ON OFF button Pressing this button will turn on or turn off the air conditioner 2 button Under cooling mode press or button to increase or decrease the temperature by 1 C F Set temperature range is 16 C 30 C Under drying or fan mode this bu...

Page 8: ...f timer function is started up the upper indicator will keep the display status Others it won t be displayed Under timer mode press timer button again to cancel timer mode 6 Sleep Press sleep button to enter into sleep mode If the controller operates at cooling mode after sleep mode is started up preset temperature will increase by 1 C within 1 hour preset temperature will increase by 2 C within 2...

Page 9: ...tatus pressing the button on the remote controller the signal icon on the display of remote controller will blink once and the air conditioner will give out a de sound which means the signal has been sent to the air conditioner Under OFF status set temperature and clock icon will be displayed on the display of remote controller If timer on timer off and light functions are set the corresponding ic...

Page 10: ...sted under Dry mode 5 X FAN button Press this button under cool and dry mode to start up x fan function Press this button again to cancel x fan function Note When x fan function is on if the air conditioner is turned off indoor fan will still operate at low speed for a while to blow the residual water inside the air duct During x fan operation press X FAN button to turn off x fan function Indoor f...

Page 11: ...y will turn ON or turn OFF child lock function When child lock function is started up LOCK indicator on remote controller is ON If you operate the remote controller remote controller won t send signal Temperature display switchover function Under OFF status pressing button and MODE button simultaneously can switch between C and F OPERATION GUIDE 1 After putting through the power press ON OFF butto...

Page 12: ...wise it may cause electric shock Do not wash air conditioner with water Otherwise it may cause electric shock Do not use volatile liquid such as thinner or gas to clean the air conditioner Otherwise it may damage the appearance of air conditioner Clean outer case and grille Clean outer case If there s dust on the surface of outer case please use soft towel to wipe it If the outer case is very dirt...

Page 13: ...eason 1 Disconnect power supply 2 Clean filter and outer case 3 Remove dust and other impurities from the air conditioner 4 Eliminate accumulated water in chassis refer to the section of Drainage way for details 5 Check whether window bracket is damaged or not If yes please contact dealer Long time storage If you don t use the air conditioner for a long time please maintain it by following steps f...

Page 14: ...14 English MALFUNCTION ANALYSIS Please check below items before asking for maintenance If the malfunction still can t be eliminated please contact local dealer or qualified professionals ...

Page 15: ...for the unit been set properly Adjust the temperature Are doors and windows closed Close door and window Air conditioner can t receive signal from remote controller or remote controller is not sensible Is normal operation interrupted by events such as static pressure unstable voltage Please pull out the plug Insert the plug after about 3min and then turn on the unit Is the remote controller within...

Page 16: ...e unit is interfered by thunder radio etc Disconnect power put through the power again and then turn on the unit again You can heard water flowing sound Hearing a sound right after turning on or off There s flowing sound of refrigerant inside the air conditioner which is the normal phenomenon You can heard the sound of brekage Hearing a sound right after turning on or off Heat expansion or shrinka...

Page 17: ...or operation 3 If the malfunction still occur please contact our after sales service center E8 Overload malfunction F4 Outdoor tube temperature sensor is open short circuited Please contact after sale service person to deal with it WARNING If there re following phenomenon please turn off the air conditioner and disconnect the power immediately and then contact dealer immediately Power cord is over...

Page 18: ...igh humidy can cause malfuncion Requirements for electric connection Safety precaution 1 Must follow the electric safety regulations when installing the unit 2 According to the local safety regulations use qualified power supply circuit 3 If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard 4 Properly conn...

Page 19: ...installation Accessory list joint A wire hook 2 screw 3 pipe clip rubber plug pipe hoop 2 user s manual remote controller drainage pipe cross screwdriver gauge straight screwdriver scissors saw pencil battery 2 AAA 1 5V joint B joint C heat discharge pipe Adapter 1 Tools needed for installation ...

Page 20: ...mble the wire hook at the back of the unit with screws the direction of wire hook is as shown in following fig direction of wire hook is upward wire hook screw direction of wire hook is downward Wind the power cord around the wire hook ...

Page 21: ...using otherwise poor drainage will affect normal operation of the unit Instructions for drainage pipe installation as follows 1 Remove the rubber plug at drainage port drainage port 2 Fix the drainage pipe clip on the right of rear side plate near drainage port with a screw drainage port drainage pipe clip screw 3 Put the drainage pipe into drainage port and screw it up and then bind it with pipe ...

Page 22: ...ondensation water will be accumulated inside the chassis and you do not need to discharge the water frequently 2 When the chassis is full with water the buzzer will give out 8 sounds and H8 is displayed to remind user to discharge water Move the unit to a suitable place for emptying of water do not tilt the unit and keep it horizontal during moving Take the drainage pipe from the clip and pull out...

Page 23: ...cluded in the package the spout by turning clockwise 3 Insert the drainage hose into drain connector ATTENTION When using continuous drainage option from the middle hole place portable on a level surface and make sure garden hose is clear of any obstructions and is directed downward Placing portable on an uneven surface or improper hose installation may result in water filling up the chassis and c...

Page 24: ...C clockwise joint A clasp groove the side with TOP is upwards heat discharge pipe 2 Insert joint A of heat discharge pipe the side with TOP is upwards into the groove until you hear a klikk sound 3 Aim the locating pole of joint B of heat discharge pipe at the opening of joint C rotate it slightly to make joint B and joint C connect tightly joint B C tightened status opening locating pole ...

Page 25: ...as possible and flat without curve to ensure smooth heat discharge correct correct correct wrong The length of the heat discharge pipe is less than 1m It is recommended to use it with shortest length When installing heat discharge pipe should be as flat as possible Don t prolong the pipe or connect it with other heat discharge pipe ...

Page 26: ...130cm from floor Wrong installation is shown in following figure If the pipe is bent too much it would easily cause malfunction Disassemble heat discharge pipe 1 Remove joint B remove joint B from joint C 2 Remove joint A Press the clasp and lift joint A upwards to remove it disassemble upwards joint A clasp joint B C ...

Page 27: ...27 English ELECTRIC SCHEMATIC DIAGRAM Cool 7 Cool 12 ...

Page 28: ...28 English ...

Page 29: ...vailable Engelsk Engelsk English English This marking indicates that this product should not be disposed with other household wastes throughout the EU To prevent possible harm to the environment or human health from uncontrolled waste disposal recycle it responsibly to promote the sustainable reuse of material resources To return your used device please use the return and collection systems or con...