20
INSTALLATION
INSTRUCTIONS
Back Panel
3.4.5
If the appliance is being fiMed using the rear flue opon, the closure plate can
be used to seal either a 16” 22” opening or a 12” x 22” opening (precast) The back
panel should be produced from
non combus;ble
material and be smooth and flat
to allow adhesion of the closure plate to its surface.
Debris
3.4.6
Debris should be removed during every annual service. In the case of rear
vent installaons, the closure plate should be removed and debris removed. This
may not be necessary for precast flue installaons as very liMle debris will be
accumulate. In the case of top flue installaons, the register plate access hatch
should be removed and all debris removed. It is advisable that during this process
the debris guard fiMed to the top of the flue pipe (if applicable) should be checked
for debris blockage or damage and replaced if necessary.
Venlaon
3.5
No purpose made venlaon is required for this product as the nominal input
does not exceed 7.0 kW, however if spillage is detected during the installaon
commissioning it may be necessary to provide some addional venlaon. Always
check the current rules in force for the country of installaon.
3.6
This appliance is suitable for use on natural gas (G20) only from a governed
meter. It is the responsibility of the installer to ensure that correct pipe sizing has
been supplied to the site for correct performance. 8mm diameter ducle copper
tubing should be used for the run to the appliance at a maximum length of 500mm
to avoid pressure drops. The appliance is supplied with a restricon device which
must be used as part of the installaon. There should be no soldered joints within
the firebox of the appliance.
Gas Supply