INSTALLATION
INSTRUCTIONS
Combusbles
This
drawing
shows
the
minimum
clearances
from
combusble
materials.
A
minimum clearance of 50mm
must be le at the rear of the
appliance (from the back vercal
face). The rear wall must not be
made
from
combusble
materials, this wall
must
be non
combusble.
IMPORTANT NOTE:
The register plate, or top panel
of the chamber MUST be non
combusble.
The
150mm
dimension
shown
on
this
diagram pertains to combusble
mantels or beams level or in
front of the appliance.
This
150mm
clearance
is
sasfactory for mantels siBng up
to 75mm in front of the
appliance glass. If this shelf/
mantel/beam projects further
than 75mm from the glass face
then the clearance must be
increased by a similar amount.
This
drawing
shows
the
minimum clearances from non
combusble
materials.
A
minimum clearance of 50mm
must be le at the rear of the
appliance (from the back vercal
face). The rear wall must not be
made
from
combusble
materials, this wall must be non
combusble.
It is recommended that the side
wall clearance is made larger if
possible as this will allow more
airflow to and around the
appliance.
3.4.4
The following drawings show the recommended
fireplace openings
required
from combusbles and non combusbles for installaon.
Clearances
Non Combusbles
For example, shelf projecon = 100mm
Clearance must be 175mm
(to the shelfs nearest point).