P E R F O R M A N C E
WILDEN PUMP & ENGINEERING, LLC
12
PX1500
Performance
SET
TING 4 PERFORMANCE CUR
VE
EMS CUR
VE
PX1
50
0 ALUMINUM
RUBBER-FITTED
TECHNIC
AL D
A
T
A
Height
. . . . . . . . . . . . . . . . . . . . . . . . .
1031 mm (40.6”)
Width
. . . . . . . . . . . . . . . . . . . . . . . . . . .
615 mm (24.2”)
Depth
. . . . . . . . . . . . . . . . . . . . . . . . . . .
422 mm (16.6”)
Ship W
eight
. . . . . . . . . . .
Aluminum 83 kg (182 lbs.)
Aluminum Drop-In 70 kg (152 lbs.)
Air Inlet
. . . . . . . . . . . . . . . . . . . . . . . . . .
19 mm (3/4”)
Inlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
76 mm (3”)
Outlet
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
76 mm (3”)
Suction Lift
. . . . . . . . . . . . . . . . . . . . .
6.1 m Dry (19.9’)
8.8 m W
et (28.9’)
Disp. Per Stroke
. . . . . . . . . . . . . . . .
5.22 l (1.38 gal.)
1
Max. Flow Rate
. . . . . . . . . . . . . .
1021 lpm (270 gpm)
Max. Size Solids
. . . . . . . . . . . . . . . . .
12.7 mm (1/2”)
1
Displacement per stroke was calculated at 4.8 bar (70 psig)
air inlet pressure against a 2 bar (30 psig) head pressure.
The Effi
ciency Management System (EMS)
can be used to optimize the performance of
your Wilden pump for specifi
c applications.
The pump is delivered with the EMS adjusted
to setting 4, which allows maximum fl
ow
.
The EMS curve allows the pump user to deter
-
mine fl
ow and air consumption at each EMS
setting. For any EMS setting and discharge
pressure, the “X factor” is used as a multi-
plier with the original values from the setting
4 performance curve to calculate the actual
fl ow and air consumption values for that spe-
cifi
c EMS setting. Note: you can interpolate
between the setting curves for operation at
intermediate EMS settings.
EXAMPLE
A PX1500 aluminum, Rubber
-fi
tted pump operating at EMS setting 4,
achieved a fl
ow rate of 640 lpm (169 gpm) using 192 Nm
3
/h (113 scfm)
of air when run at 5.5 bar (80 psig) air inlet pressure and 2.1 bar
(30 psig) discharge pressure (See dot on performance curve).
The end user did not require that much fl
ow and wanted to reduce
air consumption at his facility
. He determined that EMS setting 2
would meet his needs. At 2.1 bar (30 psig) discharge pressure and
EMS setting 2, the fl
ow “X factor” is 0.67 and the air “X factor” is
0.52 (see dots on EMS curve).
Multiplying the original setting 4 values by the “X factors” provides
the setting 2 fl
ow rate of 429 lpm (113 gpm) and an air consumption
of 100 Nm
3
/h (59 scfm). The fl
ow rate was reduced by 33% while
the air consumption was reduced by 48%, thus providing increased
effi
ciency
.
For a detailed example for how to set your EMS, see beginning of
performance curve section.
Caution: Do not exceed 8.6 bar (125 psig) air supply pressure.