S U G G E S T E D I N S T A L L A T I O N
NOTE:
In the event of a power failure, the shut off valve
should be closed, if the restarting of the pump is not
desirable once power is regained.
AIR OPERATED PUMPS:
To stop the pump from
operating in an emergency situation, simply close the
shut off valve (user supplied) installed in the air supply
line. A properly functioning valve will stop the air supply
to the pump, therefore stopping output. This shut off
valve should be located far enough away from the
pumping equipment such that it can be reached safely
in an emergency situation.
NEEDLE VALVE
AIR SHUT OFF VALVE
FOOTPAD
COMBINATION
FILTER & REGULATOR
SUCTION
MUFFLER
FLEXIBLE
CONNECTION
FLEXIBLE
CONNECTION
GAUGE
(OPTIONAL)
EQUALIZER
SURGE DAMPENER
(OPTIONAL)
SHUT OFF
VALVE
DISCHARGE
This illustration is a generic
representation of an air-operated
double-diaphragm pump.