6 . Place the smoke ring in the smoke outlet hole in the back of the stove and secure it with the
three screws .
7 . Replace the top plate on the stove .
A top cover can be bought as an accessory to cover the hole in the top plate of the stove if the
stove is connected to a rear smoke outlet .
General Information
When installing your WIKING wood-burning stove, you must ensure that all local regulations,
including those referring to national and European standards, are observed . It is always a
good idea to consult a chimney sweep before installing your stove, as it is he/she who must
ultimately approve the installation . Always follow the instructions of the manual carefully and
make sure that the installation is carried out by a qualified professional. WIKING packaging
material should always be handled in accordance with the local rules for waste handling .
Room Requirements
It must always be possible to deliver fresh combustion air to the room in which the wood-
burning stove is to be installed . A window that can be opened or an adjustable air valve is
considered to be sufficient. The adjustable air valve/air grate must not be blocked. Exhaust
fans running in the same room as where the stove is installed may cause problems .
Technical Data
If the wood-burning stove is to be placed on a floor made of combustible material, the area
around the stove must be covered with a non-combustible material. The floor construction
must also be able to withstand the weight of the stove and the chimney . The chimney’s weight
must be calculated in relation to dimension and height .
In the table below you’ll find important information about your wood-burning stove.
Weight
Dimension (h x w x d)
Distance to furniture - in
front
Mini 2 with a base
73 kg
60.8 x 46.8 x 35.6 cm
100 cm
Mini 2 with short legs
73 kg
65.2 x 46.8 x 35.6 cm
100 cm
Mini 2 with long legs
74 kg
83.2 x 51.7 x 37.1 cm
100 cm
The stove is mainly made of sheet iron, with some items made of cast iron .
Nominal heat output:
4 .5 kW according to EN norm
Flue gas temperature
EN 13240 measurement point:
236
o
C
Flue gas temperature
measured in the outlet socket:
283
o
C
Exhaust gas mass flow:
3,6 g/s
Gross and net efficiency:
76% / 83%